Step 9.
Install and lock the left-side cover (see “Installing the left-side cover” on page 183).
If you have replaced a server component or installed an optional device in the server, you need to reconnect
the power cords and all external cables, and turn on the server and peripheral devices.
Note:
You must wait approximately 3 minutes after you connect the server power cord to an electrical outlet
before the power-control button becomes active.
Removing an optional ServeRAID adapter memory module
Use this information to remove an optional ServeRAID adapter memory module.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove an optional ServeRAID adapter memory module, complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention:
Do not allow the server to fall over.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 182).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 188).
Step 4.
Remove the adapter (see “Removing an adapter” on page 215).
Step 5.
Grasp the memory module and lift to remove it from the connector on the ServeRAID adapter.
ServeRAID adapter
Retention
bracket
ServeRAID
memory module
Figure 143. Memory card removal
If you are instructed to return the server component or optional device, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing an optional ServeRAID adapter memory module
Use this information to install an optional ServeRAID adapter memory module.
Removing and replacing components
223
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......