816f0a13-0301xxxx : System [ComputerSystemElementName] has recovered from a Fatal Bus
Error. (CPU 1 PECI)
This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130301xxxx or 0x816f0a130301xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
•
816f0a13-0302xxxx : System [ComputerSystemElementName] has recovered from a Fatal Bus
Error. (CPU 2 PECI)
This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130302xxxx or 0x816f0a130302xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
Appendix A. Integrated Management Module II (IMM2) error messages
1015
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......