No action; information only.
•
806f0125-0c01xxxx : [ManagedElementName] detected as absent. (Front Panel)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01250c01xxxx or 0x806f01250c01xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0392
User Response
Please ensure the PCI riser 1 has been installed correctly.
•
806f0207-0301xxxx : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02070301xxxx or 0x806f02070301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix:
PLAT
ID:
0044
User Response
Appendix A. Integrated Management Module II (IMM2) error messages
503
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......