Table 16. CD/DVD drive's symptoms and actions (continued)
Symptom
Action
4. Reseat the DVD drive.
5. Replace the DVD drive.
The DVD drive tray is not
working.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release opening.
3. Reseat the DVD drive.
4. Replace the DVD drive.
General problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by '(Trained technician only)', that step must be performed only by a Trained
technician.
• Go to the IBM support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Table 17. General symptoms and actions
Symptom
Action
A cover latch is broken, an
LED is not working, or a similar
problem has occurred.
If the part is a CRU, replace it. If the part is a microprocessor or the system board,
the part must be replaced by a trained technician.
The server is hung while the
screen is on. Cannot start the
Setup utility by pressing F1.
1. See “Nx-boot failure” on page 162 for more information.
2. See “Recovering the server firmware (UEFI update failure)” on page 160 for
more information.
GPU/VGA adapter problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by '(Trained technician only)', that step must be performed only by a Trained
technician.
• Go to the IBM support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Table 18. GPU/VGA adapter symptoms and actions
Symptom
Action
Seeing the
Yellow Band
or the
SLOT ERR LED
is lit up in the
slot during the installation of 2x
nVIDA K20c.
1. Enable PCI 64 bit resource.
2. Change the option ROM execution order (
slot 5
➙
slot 7
➙
slot 2
) if you
operate in
Legacy mode only OS
.
The system hanged or seeing
Yellow Band
in slot 7 or
no video output during the
installation of nVIDA Q series
or K series.
Disable PCI 64 bit resource (except for nVIDA K20c).
146
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......