Attention:
Do not allow the server to fall over.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 182).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 188).
Step 4.
Align the guides on the fan cage with the release latch to the open position.
Step 5.
Put the fan cage assembly down into the server.
Note:
Make sure that the fan cage is fully seated.
Step 6.
Rotate the fan cage release latch to the close position. The fan cage will be fully seated when it
is secured.
00
00
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00
0
0
00
00
00
00
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
1
2
Fan cage assembly
Figure 181. Fan cage installation
Step 7.
Connect the fan cage assembly power cable to the system board (see “Internal cable routing and
connectors” on page 33).
Step 8.
Install the air baffle (see “Replacing the air baffle” on page 189).
Step 9.
Install and lock the left-side cover (see “Installing the left-side cover” on page 183).
If you have replaced a server component or installed an optional device in the server, you need to reconnect
the power cords and all external cables, and turn on the server and peripheral devices.
Removing the left-side cover/power cut-off switch assembly
Use this information to remove the left-side cover/power cut-off switch assembly.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove the left-side cover/power cut-off switch assembly, complete the following steps.
Removing and replacing components
263
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......