Table 12. Light path diagnostics panel LEDs (continued)
LED
Description
Action
Configu
Microprocessor
A hardware configuration error
has occurred.
If the Configuration LED and the Microprocessor LED are
lit, complete the following steps to correct the problem:
1. Check the microprocessors that were just installed
to make sure that they are compatible with each
other (see “Installing a microprocessor and heat
sink” on page 276 for additional information about
microprocessor requirements).
2. (Trained technician only) Replace the incompatible
microprocessor.
3. Check the system-event logs for information about
the error (see “Event logs” on page 139). Replace
any component that is identified in the error log.
Configu Memory
A hardware configuration error
has occurred.
If the Configuration LED and the Memory LED are lit,
check the system-event logs for information about the
error (see “Event logs” on page 139).
Configuration
Configu Power supply
A hardware configuration error
has occurred.
If the Configuration LED and the Power supply LED are
lit, the system issues an invalid power configuration error.
Make sure that both power supplies installed in the server
are of the same rating or wattage.
When only the Memory LED
is lit, a memory error has
occurred.
Note:
Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait
10 seconds before restarting the server.
If the Configuration LED is not lit, the system might detect
a memory error. Complete the following steps to correct
the problem:
1. Reseat or swap the DIMMs with lit LEDs.
2. Check the system-event logs for information about
the error (see “Event logs” on page 139).
3. Update the server firmware to the latest level (see
“Updating the firmware” on page 103 for more
information).
4. Replace the failing DIMM (see “Installing a DIMM”
Memory
Configuration
When both the Memory and
Configuration LEDs are lit,
the memory configuration is
invalid.
If the Memory LED and the Configuration LED are lit,
check the system-event logs for information about the
error (see “Event logs” on page 139).
135
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......