50
CIM Information
Prefix:
PLAT
ID:
0446
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page by restarting the server.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
•
806f0607-0301xxxx : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName]
has asserted. (CPU 1)
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070301xxxx or 0x806f06070301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix:
PLAT
ID:
0816
User Response
1. Update the latest level of system firmware and device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster
solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Appendix A. Integrated Management Module II (IMM2) error messages
625
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......