Table 39. Events that automatically notify Support (continued)
Event ID
Message String
Automatically
Notify Support
806f010d-040bxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 11)
Yes
806f010d-040cxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 12)
Yes
806f010d-040dxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 13)
Yes
806f010d-040exxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 14)
Yes
806f010d-040fxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 15)
Yes
806f010d-0410xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 16)
Yes
806f010d-0411xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 17)
Yes
806f010d-0412xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 18)
Yes
806f010d-0413xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 19)
Yes
806f010d-0414xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 20)
Yes
806f010d-0415xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 21)
Yes
806f010d-0416xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 22)
Yes
806f010d-0417xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 23)
Yes
806f010d-0418xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 24)
Yes
806f010d-0419xxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 25)
Yes
806f010d-041axxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 26)
Yes
806f010d-041bxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 27)
Yes
806f010d-041cxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 28)
Yes
806f010d-041dxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 29)
Yes
806f010d-041exxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 30)
Yes
806f010d-041fxxxx
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 31)
Yes
806f0207-0301xxxx
[ProcessorElementName] has Failed with FRB1/BIST
condition. (CPU 1)
Yes
Appendix A. Integrated Management Module II (IMM2) error messages
299
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......