Serviceable
Yes
Automatically notify support
No
Related links
–
–
–
•
202-803-000 : MemStr Test Aborted
User pressed Ctrl-C.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Related links
–
–
–
•
202-901-000 : MemStr Test Failed
Test Failed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Execute the standard DSA memory diagnostics to validate all memory.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system on.