rich set of diagnostic tests of the major components of the server. DSA Preboot collects the following
information about the server:
– Drive health information
– Event logs for ServeRAID controllers and service processors
– IMM2.1 configuration information
– IMM2.1 environmental information
– Installed hardware, including PCI and USB information
– Light path diagnostics status
– Microprocessor, input/output hub, and UEFI error logs
– Network interfaces and settings
– Option card driver and firmware information
– RAID controller configuration
– Service processor (Integrated Management Module II (IMM2)) status and configuration
– System configuration
– Vital product data, firmware, and UEFI configuration
DSA Preboot also provides diagnostics for the following system components (when they are installed):
1. Emulex network adapter
2. IMM2.1 I2C bus
3. Light path diagnostics panel
4. Memory modules
5. Microprocessors
6. Optical devices (CD or DVD)
7. SAS or SATA drives
8. LSI controller
9. Broadcom network adapter
10. FusionIO storage
11. Intel GPU
12. Nvidia GPU
See “Running DSA Preboot diagnostic programs” on page 143 for more information on running the
DSA Preboot program on the server.
•
Troubleshooting by symptom
These tables list problem symptoms and actions to correct the problems. See “Troubleshooting by
symptom” on page 145 for more information.
Light path diagnostics
Light path diagnostics is a system of LEDs on various external and internal components of the server that
leads you to the failed component. When an error occurs, LEDs are lit along the path of the front panel, the
light path diagnostics panel, then on the failed component. By viewing the LEDs in a particular order, you
can often identify the source of the error.
When LEDs are lit to indicate an error, they remain lit when the server is turned off, provided that the server is
still connected to power and the power supply is operating correctly.
131
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......