3
1
2
Operator information
panel assembly
Release latch
Figure 169. Operator information panel installation
Step 7.
Rotate the operator information panel assembly to the server chassis until clicks into place.
Step 8.
Connect the operator information panel assembly cable to the system board (see “System-board
internal connectors” on page 25 and “Internal cable routing and connectors” on page 33).
Step 9.
Reinstall the DVD drive (see “Installing a DVD drive” on page 207 and “Installing an optional tape
drive” on page 211) which you removed before in drive bay 1.
Step 10. Connect the drive cables to the back of the drive bay 1.
Step 11. Reinstall the fan cage assembly (see “Installing the fan cage assembly” on page 262).
Step 12. Reinstall the air baffle (see “Replacing the air baffle” on page 189).
Step 13. Close the bezel (see “Replacing the air baffle” on page 189).
Step 14. Close and lock the left-side cover (see “Installing the left-side cover” on page 183).
If you have replaced a server component or installed an optional device in the server, you need to reconnect
the power cords and all external cables, and turn on the server and peripheral devices.
Removing a memory module
Use this information to remove a memory module.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove a dual inline memory module (DIMM), complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention:
Do not allow the server to fall over.
250
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......