H3C UniServer R4900 G5 Server 

Processor Installation Quick Start 

 

 

 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New H3C Technologies Co., Ltd.  
http://www.h3c.com 
 
Document version: 6W100-20210712

 

 

Summary of Contents for UniServer R4900 G5

Page 1: ...H3C UniServer R4900 G5 Server Processor Installation Quick Start New H3C Technologies Co Ltd http www h3c com Document version 6W100 20210712...

Page 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Page 3: ...red syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you select one or none x y As...

Page 4: ...switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller...

Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Page 6: ...i Content Overview 1 Processor kit 1 Preparing for installation 1 Installing the processor 2 Installing DIMMs 8 Starting the server 9...

Page 7: ...personnel and professional server engineers can install a processor When installing or removing the processors wear a reliably grounded ESD wrist strap and a pair of ESD gloves to prevent ESD damage...

Page 8: ...r baffle and then lift the air baffle up to remove it from the chassis Figure1 2 Removing the chassis air baffle Installing the processor CAUTION The server can use one or two processors To prevent da...

Page 9: ...ure1 3 Removing the protective cover 2 Install the retaining bracket onto the heatsink a As shown in Figure1 4 align the alignment triangle on the retaining bracket with the cut off corner of the heat...

Page 10: ...to a processor always hold the processor by the edges Never touch the gold contacts on the processor bottom a Tilt the processor align the small triangle on the processor with the alignment triangle i...

Page 11: ...the processor socket cover CAUTION Be careful not to touch the pins on the processor socket when you wear ESD gloves to remove the processor socket cover The pins on the processor socket are very fra...

Page 12: ...atsink onto the server a Align the alignment triangle on the retaining bracket with the cut off corner of the processor socket and the pin holes in the heatsink with the guide pins on the processor so...

Page 13: ...place Figure1 11 Locking the heatsink c Use a T30 Torx screwdriver to fasten the four captive screws on the heatsink CAUTION The screwdriver torque is in the range of 6 to 12 in lb As a best practice...

Page 14: ...lling DIMMs After you install a new processor install DIMMs for it For the DIMM installation guidelines see the server user guide To install a DIMM 1 Open the retaining clips of the DIMM slot Figure1...

Page 15: ...cannot insert the DIMM into the slot easily the installation might be wrong Re orient the DIMM and then insert it into the slot again Figure1 14 Installing a DIMM Starting the server 1 Install the ch...

Page 16: ...locking lever The access panel will automatically slide toward the server front to secure itself into place c Optional Lock the locking lever Use a Phillips screwdriver to turn the screw on the lever...