B-72
T60 Transformer Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
C8C8
...Repeated for Direct Input 15
C8CC
...Repeated for Direct Input 16
C8D0
...Repeated for Direct Input 17
C8D4
...Repeated for Direct Input 18
C8D8
...Repeated for Direct Input 19
C8DC
...Repeated for Direct Input 20
C8E0
...Repeated for Direct Input 21
C8E4
...Repeated for Direct Input 22
C8E8
...Repeated for Direct Input 23
C8EC
...Repeated for Direct Input 24
C8F0
...Repeated for Direct Input 25
C8F4
...Repeated for Direct Input 26
C8F8
...Repeated for Direct Input 27
C8FC
...Repeated for Direct Input 28
C900
...Repeated for Direct Input 29
C904
...Repeated for Direct Input 30
C908
...Repeated for Direct Input 31
C90C
...Repeated for Direct Input 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0
Direct Input/Output Channel 1 CRC Alarm Function
0 to 1
---
1
F102
0 (Disabled)
CAD1
Direct Input/Output Channel 1 CRC Alarm Message Count
100 to 10000
---
1
F001
600
CAD2
Direct Input/Output Channel 1 CRC Alarm Threshold
1 to 1000
---
1
F001
10
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
0 to 1
---
1
F102
0 (Disabled)
CAD4
Reserved (4 items)
1 to 1000
---
1
F001
10
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
0 to 1
---
1
F102
0 (Disabled)
CAD9
Direct Input/Output Channel 2 CRC Alarm Message Count
100 to 10000
---
1
F001
600
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
1 to 1000
---
1
F001
10
CADB
Direct Input/Output Channel 2 CRC Alarm Events
0 to 1
---
1
F102
0 (Disabled)
CADC
Reserved (4 items)
1 to 1000
---
1
F001
10
CAE0
Direct Input/Output Ch 1 Unreturned Messages Alarm
Function
0 to 1
---
1
F102
0 (Disabled)
CAE1
Direct Input/Output Ch 1 Unreturned Messages Alarm Msg
Count
100 to 10000
---
1
F001
600
CAE2
Direct Input/Output Ch 1 Unreturned Messages Alarm
Threshold
1 to 1000
---
1
F001
10
CAE3
Direct Input/Output Ch 1 Unreturned Messages Alarm
Events
0 to 1
---
1
F102
0 (Disabled)
CAE4
Reserved (4 items)
1 to 1000
---
1
F001
10
CAE8
Direct Input/Output Ch 2 Unreturned Messages Alarm
Function
0 to 1
---
1
F102
0 (Disabled)
CAE9
Direct Input/Output Ch 2 Unreturned Messages Alarm Msg
Count
100 to 10000
---
1
F001
600
CAEA
Direct Input/Output Ch 2 Unreturned Messages Alarm
Threshold
1 to 1000
---
1
F001
10
CAEB
Direct Input/Output Channel 2 Unreturned Messages Alarm
Events
0 to 1
---
1
F102
0 (Disabled)
CAEC
Reserved (4 items)
1 to 1000
---
1
F001
10
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID (GOID)
---
---
---
F209
“Remote Device
1“
CB21
Remote Device 1 GOOSE Ethernet APPID
0 to 16383
---
1
F001
0
CB22
Remote Device 1 GOOSE Dataset
0 to 16
---
1
F184
0 (Fixed)
CB23
Remote Device 1 in PMU Scheme
0 to 1
---
1
F126
0 (No)
CB24
Reserved
0 to 3
---
1
F626
0 (None)
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
Table B–10: MODBUS MEMORY MAP (Sheet 64 of 73)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for T60
Page 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...