GE Multilin
T60 Transformer Protection System
2-13
2 PRODUCT DESCRIPTION
2.2 ORDER CODES
2
2.2.3 ORDER CODES WITH PROCESS BUS MODULES
The order codes for the horizontal mount units with the process bus module are shown below.
MOUNT/COATING
V
|
|
|
|
|
|
Vertical (3/4 rack)
B
|
|
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
FACEPLATE/ DISPLAY
F
|
|
|
|
|
English display
D
|
|
|
|
|
French display
R
|
|
|
|
|
Russian display
A
|
|
|
|
|
Chinese display
K
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
I
|
|
|
|
|
Enhanced front panel with German display
J
|
|
|
|
|
Enhanced front panel with German display and user-programmable pushbuttons
POWER SUPPLY
H
|
|
|
|
125 / 250 V AC/DC power supply
L
|
|
|
|
24 to 48 V (DC only) power supply
ENHANCED DIAGNOSTICS CT/VT DSP
(requires all DSP to be enhanced diagnostic)
XX
|
XX
|
No DSP module (slots F and M only)
8L
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
8M
|
8M
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
8N
|
8N
|
Standard 8CT with enhanced diagnostics
8R
|
8R
|
Sensitive Ground 8CT with enhanced diagnostics
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
No Module
4A
4A
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
4D
16 digital inputs with Auto-Burnishing (maximum of three modules within a case)
4L
4L
4L
14 Form-A (no monitoring) Latching outputs
67
67
67
8 Form-A (no monitoring) outputs
6A
6A
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
6B
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
6C
6C
8 Form-C outputs
6D
6D
6D
16 digital inputs
6E
6E
6E
4 Form-C outputs, 8 digital inputs
6F
6F
6F
8 Fast Form-C outputs
6G
6G
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6H
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
6K
6K
4 Form-C and 4 Fast Form-C outputs
6L
6L
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
6M
6M
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
6N
6N
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6P
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
6R
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
6S
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
6T
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6U
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
6V
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
TRANSDUCER
INPUTS/OUTPUTS
(select a maximum of 3 per unit)
5A
5A
5A
4 DCmA inputs, 4 DCmA outputs (only one 5A module is allowed)
5C
5C
5C
8 RTD inputs
5D
5D
5D
4 RTD inputs, 4 DCmA outputs (only one 5D module is allowed)
5E
5E
5E
4 RTD inputs, 4 DCmA inputs
5F
5F
5F
8 DCmA inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
For the last module, rear slot P is used for digital input/output
modules; rear slot R is used for inter-relay communications
modules.
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
Table 2–6: T60 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS)
T60
-
*
**
- *
*
* - F
**
- H
**
- M
**
- P
**
- U
**
- W/X
**
Full Size Horizontal Mount
BASE UNIT
T60
|
|
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U
|
|
|
|
|
|
|
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
V
|
|
|
|
|
|
|
|
|
|
RS485 and Three 10/100Base-T (SFP with RJ45)
SOFTWARE
00
|
|
|
|
|
|
|
|
|
No Software Options
01
|
|
|
|
|
|
|
|
|
Ethernet Global Data (EGD)
03
|
|
|
|
|
|
|
|
|
IEC 61850
04
|
|
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850
06
|
|
|
|
|
|
|
|
|
Phasor Measurement Unit (PMU)
07
|
|
|
|
|
|
|
|
|
IEC 61850 communications and Phasor Measurement Unit (PMU)
10
|
|
|
|
|
|
|
|
|
Synchrocheck
11
|
|
|
|
|
|
|
|
|
Synchrocheck and IEC 61850
20
|
|
|
|
|
|
|
|
|
Six windings
21
|
|
|
|
|
|
|
|
|
Six windings and Ethernet Global Data (EGD) protocol
22
|
|
|
|
|
|
|
|
|
Six windings and IEC 61850 protocol
23
|
|
|
|
|
|
|
|
|
Six windings, Ethernet Global Data (EGD) protocol, and IEC 61850 protocol
33
|
|
|
|
|
|
|
|
|
Phasor Measurement Unit (PMU) and synchrocheck
34
|
|
|
|
|
|
|
|
|
Phasor Measurement Unit (PMU), IEC 61850 protocol, and synchrocheck
A0
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
A3
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
A6
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Phasor Measurement Unit (PMU)
Table 2–5: T60 ORDER CODES (REDUCED SIZE VERTICAL UNITS)
T60
-
*
**
- *
*
* - F
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
Summary of Contents for T60
Page 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...