GE Multilin
T60 Transformer Protection System
B-39
APPENDIX B
B.4 MEMORY MAPPING
B
5808
...Repeated for FlexLogic Timer 2
5810
...Repeated for FlexLogic Timer 3
5818
...Repeated for FlexLogic Timer 4
5820
...Repeated for FlexLogic Timer 5
5828
...Repeated for FlexLogic Timer 6
5830
...Repeated for FlexLogic Timer 7
5838
...Repeated for FlexLogic Timer 8
5840
...Repeated for FlexLogic Timer 9
5848
...Repeated for FlexLogic Timer 10
5850
...Repeated for FlexLogic Timer 11
5858
...Repeated for FlexLogic Timer 12
5860
...Repeated for FlexLogic Timer 13
5868
...Repeated for FlexLogic Timer 14
5870
...Repeated for FlexLogic Timer 15
5878
...Repeated for FlexLogic Timer 16
5880
...Repeated for FlexLogic Timer 17
5888
...Repeated for FlexLogic Timer 18
5890
...Repeated for FlexLogic Timer 19
5898
...Repeated for FlexLogic Timer 20
58A0
...Repeated for FlexLogic Timer 21
58A8
...Repeated for FlexLogic Timer 22
58B0
...Repeated for FlexLogic Timer 23
58B8
...Repeated for FlexLogic Timer 24
58C0
...Repeated for FlexLogic Timer 25
58C8
...Repeated for FlexLogic Timer 26
58D0
...Repeated for FlexLogic Timer 27
58D8
...Repeated for FlexLogic Timer 28
58E0
...Repeated for FlexLogic Timer 29
58E8
...Repeated for FlexLogic Timer 30
58F0
...Repeated for FlexLogic Timer 31
58F8
...Repeated for FlexLogic Timer 32
Phase Time Overcurrent (Read/Write Grouped Setting
)
(6 modules)
5900
Phase Time Overcurrent 1 Function
0 to 1
---
1
F102
0 (Disabled)
5901
Phase Time Overcurrent 1 Signal Source
0 to 5
---
1
F167
0 (SRC 1)
5902
Phase Time Overcurrent 1 Input
0 to 1
---
1
F122
0 (Phasor)
5903
Phase Time Overcurrent 1 Pickup
0 to 30
pu
0.001
F001
1000
5904
Phase Time Overcurrent 1 Curve
0 to 16
---
1
F103
0 (IEEE Mod Inv)
5905
Phase Time Overcurrent 1 Multiplier
0 to 600
---
0.01
F001
100
5906
Phase Time Overcurrent 1 Reset
0 to 1
---
1
F104
0 (Instantaneous)
5907
Phase Time Overcurrent 1 Voltage Restraint
0 to 1
---
1
F102
0 (Disabled)
5908
Phase TOC 1 Block For Each Phase (3 items)
0 to 4294967295
---
1
F300
0
590F
Phase Time Overcurrent 1 Target
0 to 2
---
1
F109
0 (Self-reset)
5910
Phase Time Overcurrent 1 Events
0 to 1
---
1
F102
0 (Disabled)
5911
Reserved (3 items)
0 to 1
---
1
F001
0
5914
...Repeated for Phase Time Overcurrent 2
5928
...Repeated for Phase Time Overcurrent 3
593C
...Repeated for Phase Time Overcurrent 4
5950
...Repeated for Phase Time Overcurrent 5
5964
...Repeated for Phase Time Overcurrent 6
Phase Instantaneous Overcurrent (Read/Write Grouped Setting) (12 modules)
5A00
Phase Instantaneous Overcurrent 1 Function
0 to 1
---
1
F102
0 (Disabled)
5A01
Phase Instantaneous Overcurrent 1 Signal Source
0 to 5
---
1
F167
0 (SRC 1)
5A02
Phase Instantaneous Overcurrent 1 Pickup
0 to 30
pu
0.001
F001
1000
5A03
Phase Instantaneous Overcurrent 1 Delay
0 to 600
s
0.01
F001
0
Table B–10: MODBUS MEMORY MAP (Sheet 31 of 73)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for T60
Page 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...