A-16
T60 Transformer Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
10375
SRC 2 Ib Harm[4]
%
Source 2 phase B current fourth harmonic
10376
SRC 2 Ib Harm[5]
%
Source 2 phase B current fifth harmonic
10377
SRC 2 Ib Harm[6]
%
Source 2 phase B current sixth harmonic
10378
SRC 2 Ib Harm[7]
%
Source 2 phase B current seventh harmonic
10379
SRC 2 Ib Harm[8]
%
Source 2 phase B current eighth harmonic
10380
SRC 2 Ib Harm[9]
%
Source 2 phase B current ninth harmonic
10381
SRC 2 Ib Harm[10]
%
Source 2 phase B current tenth harmonic
10382
SRC 2 Ib Harm[11]
%
Source 2 phase B current eleventh harmonic
10383
SRC 2 Ib Harm[12]
%
Source 2 phase B current twelfth harmonic
10384
SRC 2 Ib Harm[13]
%
Source 2 phase B current thirteenth harmonic
10385
SRC 2 Ib Harm[14]
%
Source 2 phase B current fourteenth harmonic
10386
SRC 2 Ib Harm[15]
%
Source 2 phase B current fifteenth harmonic
10387
SRC 2 Ib Harm[16]
%
Source 2 phase B current sixteenth harmonic
10388
SRC 2 Ib Harm[17]
%
Source 2 phase B current seventeenth harmonic
10389
SRC 2 Ib Harm[18]
%
Source 2 phase B current eighteenth harmonic
10390
SRC 2 Ib Harm[19]
%
Source 2 phase B current nineteenth harmonic
10391
SRC 2 Ib Harm[20]
%
Source 2 phase B current twentieth harmonic
10392
SRC 2 Ib Harm[21]
%
Source 2 phase B current twenty-first harmonic
10393
SRC 2 Ib Harm[22]
%
Source 2 phase B current twenty-second harmonic
10394
SRC 2 Ib Harm[23]
%
Source 2 phase B current twenty-third harmonic
10395
SRC 2 Ib Harm[24]
%
Source 2 phase B current twenty-fourth harmonic
10396
SRC 2 Ib Harm[25]
%
Source 2 phase B current twenty-fifth harmonic
10405
SRC 2 Ic THD
%
Source 2 phase C current total harmonic distortion
10406
SRC 2 Ic Harm[2]
%
Source 2 phase C current second harmonic
10407
SRC 2 Ic Harm[3]
%
Source 2 phase C current third harmonic
10408
SRC 2 Ic Harm[4]
%
Source 2 phase C current fourth harmonic
10409
SRC 2 Ic Harm[5]
%
Source 2 phase C current fifth harmonic
10410
SRC 2 Ic Harm[6]
%
Source 2 phase C current sixth harmonic
10411
SRC 2 Ic Harm[7]
%
Source 2 phase C current seventh harmonic
10412
SRC 2 Ic Harm[8]
%
Source 2 phase C current eighth harmonic
10413
SRC 2 Ic Harm[9]
%
Source 2 phase C current ninth harmonic
10414
SRC 2 Ic Harm[10]
%
Source 2 phase C current tenth harmonic
10415
SRC 2 Ic Harm[11]
%
Source 2 phase C current eleventh harmonic
10416
SRC 2 Ic Harm[12]
%
Source 2 phase C current twelfth harmonic
10417
SRC 2 Ic Harm[13]
%
Source 2 phase C current thirteenth harmonic
10418
SRC 2 Ic Harm[14]
%
Source 2 phase C current fourteenth harmonic
10419
SRC 2 Ic Harm[15]
%
Source 2 phase C current fifteenth harmonic
10420
SRC 2 Ic Harm[16]
%
Source 2 phase C current sixteenth harmonic
10421
SRC 2 Ic Harm[17]
%
Source 2 phase C current seventeenth harmonic
10422
SRC 2 Ic Harm[18]
%
Source 2 phase C current eighteenth harmonic
10423
SRC 2 Ic Harm[19]
%
Source 2 phase C current nineteenth harmonic
10424
SRC 2 Ic Harm[20]
%
Source 2 phase C current twentieth harmonic
10425
SRC 2 Ic Harm[21]
%
Source 2 phase C current twenty-first harmonic
10426
SRC 2 Ic Harm[22]
%
Source 2 phase C current twenty-second harmonic
10427
SRC 2 Ic Harm[23]
%
Source 2 phase C current twenty-third harmonic
10428
SRC 2 Ic Harm[24]
%
Source 2 phase C current twenty-fourth harmonic
10429
SRC 2 Ic Harm[25]
%
Source 2 phase C current twenty-fifth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 16 of 26)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for T60
Page 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...