B-28
T60 Transformer Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
3A81
...Repeated for Field Contact Input 36
3A8C
...Repeated for Field Contact Input 37
3A97
...Repeated for Field Contact Input 38
3AA2
...Repeated for Field Contact Input 39
3AAD
...Repeated for Field Contact Input 40
Field Unit Shared Inputs (Read/Write Setting) (16 modules)
3B00
Field Shared Input 1 ID
0 to 65535
---
1
F205
"SI 1"
3B06
Field Shared Input 1 Unit Origin 1
0 to 8
---
1
F256
0 (None)
3B07
Field Shared Input 1 Channel Origin 1
1 to 15
---
1
F001
1
3B08
Field Shared Input 1 Events
0 to 1
---
1
F102
1 (Enabled)
3B09
...Repeated for Field Shared Input 2
3B12
...Repeated for Field Shared Input 3
3B1B
...Repeated for Field Shared Input 4
3B24
...Repeated for Field Shared Input 5
3B2D
...Repeated for Field Shared Input 6
3B36
...Repeated for Field Shared Input 7
3B3F
...Repeated for Field Shared Input 8
3B48
...Repeated for Field Shared Input 9
3B51
...Repeated for Field Shared Input 10
3B5A
...Repeated for Field Shared Input 11
3B63
...Repeated for Field Shared Input 12
3B6C
...Repeated for Field Shared Input 13
3B75
...Repeated for Field Shared Input 14
3B7E
...Repeated for Field Shared Input 15
3B87
...Repeated for Field Shared Input 16
Field Unit Contact Outputs (Read/Write Setting) (8 modules)
3B90
Field Contact Output 1 ID (6 items)
---
---
---
F205
"FCO U /OUT"
3BB4
Field Output 1 Operate (6 items)
0 to 4294967295
---
1
F300
0
3BC0
Field Output 1 Seal In (6 items)
0 to 4294967295
---
1
F300
0
3BCC
Field Output 1 Events (6 items)
0 to 1
---
1
F102
1 (Enabled)
3BD2
...Repeated for Field Contact Output 2
3C14
...Repeated for Field Contact Output 3
3C56
...Repeated for Field Contact Output 4
3C98
...Repeated for Field Contact Output 5
3CDA
...Repeated for Field Contact Output 6
3D1C
...Repeated for Field Contact Output 7
3D5E
...Repeated for Field Contact Output 8
Field Unit Latching Outputs (Read/Write Setting) (8 modules)
3DC7
Field Latching Output 1 ID
0 to 1
---
1
F205
"FLO Ux /LO"
3DCD
Field Latching Output 1 Open
0 to 4294967295
---
1
F300
0
3DCF
Field Latching Output 1 Close
0 to 4294967295
---
1
F300
0
3DD1
Field Latching Output 1 Events
0 to 1
---
1
F102
1 (Enabled)
3DD2
Field Latching Output 1 Reserved (2 items)
0 to 1
---
1
F001
0
3DD4
...Repeated for Field Latching Output 2
3DE1
...Repeated for Field Latching Output 3
3DEE
...Repeated for Field Latching Output 4
3DFB
...Repeated for Field Latching Output 5
3E08
...Repeated for Field Latching Output 6
3E15
...Repeated for Field Latching Output 7
3E22
...Repeated for Field Latching Output 8
Field Unit Shared Outputs (Read/Write Setting) (16 modules)
3E30
Field Shared Output 1 ID
0 to 65535
---
1
F205
"SO 1"
3E36
Field Shared Output 1 Operate
0 to 4294967295
---
1
F300
0
3E38
Field Shared Output 1 Unit Dest 1
0 to 8
---
1
F256
0 (None)
Table B–10: MODBUS MEMORY MAP (Sheet 20 of 73)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for T60
Page 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...