Figure 6.6 - Example: .csv Event Display Export, Excel spreadsheet
6.6.2.1 Export Filter Out
You can filter out data you don't want or need in your text file.
(This option is available only for serial data.) In the
Filter Out
box, choose which side to filter out: the DTE data,
the DCE data or neither side (don't filter any data.) For example, if you choose the radio button for DTE data, the
DTE data would be filtered out of your export file and the file would contain only the DCE data.
You can also filter out Special Events (which is everything that is not a data byte, such as control signal changes and
Set I/O events), Non-printable characters or both. If you choose to filter out Special Events, your export file would
contain only the data bytes. Filtering out the non-printable characters means that your export file would contain
only special events and data bytes classified as printable. In ASCII, printable characters are those with hex values
between $20 and $7e.
6.6.2.2 Exporting Baudot
When exporting Baudot, you need to be able to determine the state of the shift character. In a text export, the
state of the shift bit can be determined by the data in the Character field. When letters is active, the character
field shows letters and vice versa.
TELEDYNE LECROY
Chapter 6 Saving and Importing Data
175
Frontline BPA low energy Hardware & Software User Manual