Filtering on all Frames with Errors
To filter on all frames with errors:
1. Open the
Frame Display
window.
2. Click the starred
Quick Filter
icon
or select
Quick Filtering
from the
Filter
menu
3. Check the box for
All Frames With Errors
in the
Protocols To Filter In
pane, and click
OK.
4. The system creates a tab on the
Frame Display
labeled "Errors" that displays the
results of the
All Frames With Errors
filter.
Note:
When you have multiple Frame Display windows open and you are capturing data,
you may receive an error message declaring that "Filtering cannot be done while receiving
data this fast." If this occurs, you may have to stop filtering until the data is captured.
4.3.2 low energy Timeline
The
Bluetooth low energy Timeline
displays packet information with an emphasis on temporal
information and payload throughput. The timeline also provides selected information from
Frame Display
.
The timeline provides a rich set of diverse information about low energy packets, both individually and as a
range. Information is conveyed using text, color, packet size, and position.
Figure 4.30 -
Bluetooth
low energy Timeline
You access the Timeline by selecting
Bluetooth low energy Timeline
from the
View
menu or by pressing
the
Bluetooth
low energy Timeline icon
on the
Control
window toolbar and
Frame Display
toolbar.
In computing throughput, packets that have a CRC error are excluded.
Chapter 4 Capturing and Analyzing Data
TELEDYNE LECROY
Frontline BPA low energy Hardware & Software User Manual
73
Summary of Contents for BPA LOW ENERGY