4.5.3 Opening Multiple Event Display Windows
Click the
Duplicate View
icon
from the
Event Display
toolbar to open a second
Event Display
window.
You can open as many
Event Display
windows as you like. Each
Event Display
is independent of the
others and can show different data, use a different radix or character set, or be frozen or live.
The
Event Display
windows are numbered in the title bar. If you have multiple
Event Displays
open, click
on the
Event Display
icon
on the
Control
window toolbar to show a list of all the
Event Displays
currently open. Select a window from the list to bring it to the front.
4.5.4 Calculating CRCs or FCSs
The cyclic redundancy check (CRC) is a function on the
Event Display
window used to produce a checksum.
The frame check sequence (FCS) are the extra checksum characters added to a frame to detect errors.
1. Open the
Event Display
window.
2. Click and drag to select the data for which you want to generate a CRC.
3. Click on the
CRC
icon
.
4. In the
CRC
dialog box, click on the down arrow to show the
list of choices for CRC algorithms. Choose an algorithm to use.
Choose CRC 32 (Ethernet). Choose CRC 32 (Ethernet) for
Ethernet data or the appropriate CRC type for serial data.
5. Enter a
Seed
value in hexadecimal if desired.
6. Click
OK
to generate the CRC. It appears in the byte
information lines at the bottom of the Event Display window.
Whenever you select a range of data, a CRC using the
algorithm you selected is calculated automatically.
Calculating CRC for interwoven data
4.5.5 Calculating Delta Times and Data Rates
1. Click on the E
vent Display
icon
on the
Control
window to open the
Event Display
window.
2. Use the mouse to select the data you want to calculate a delta time and rate for.
3. The
Event Display
window displays the delta time and the data rate in the status lines at the bottom
of the window.