Figure 3.14 - Parameters Added to Decoder
4. To delete a parameter from the
Initial Connections
window, select the parameter and click on the
Delete
button.
5. Decoder parameters cannot be edited. The only way to change a parameter is to delete the original as
described above, and recreate the parameter with the changed settings and selections and then click
on the
Add
button.
6.
L2CAP
parameters are saved when the template is saved.
3.2.3.2 L2CAP Override Decode Information
The
Set Subsequent Decoder Parameters
dialog allows the user to override an existing parameter at any
frame in the capture where the parameter is used.
If you have a parameter in effect and wish to change that parameter:
1. Select the frame where the change should take effect
2. Select
Set Subsequent Decoder Parameters
from
the
Options
menu, or by selecting a frame in the frame
display and choosing from the right-click pop-up menu,
and make the needed changes. Refer to
3. Change the L2CAP parameter by selecting from the rule
to change, and click on the listed parameters.
4. If you wish to remove an overridden rule click on
Remove Override
button. If you want to remove all
decoder parameter settings click on
Remove All
.
5. Click
OK
.
Each entry in the
Set Subsequent Decoder Parameters
dialog takes effect from the specified frame onward or until
redefined in this dialog on a later frame.
Note:
If the capture has no user defined overrides, then the
system displays a dialog stating that no user defined
overrides exist.
3.2.4 RFCOMM Decoder Parameters
3.2.4.1 About RFCOMM Decoder Parameters
Each entry in the
Set Initial Decoder Parameters
dialog takes effect from the beginning of the capture
onward or until redefined in the
Set Subsequent Decoder Parameters
dialog.
Chapter 3 Configuration Settings
TELEDYNE LECROY
Frontline BPA low energy Hardware & Software User Manual
25
Summary of Contents for BPA LOW ENERGY
Page 1: ...Hardware and Software User Manual Revision Date 1 3 2017...
Page 222: ......