4. To delete a parameter from the
Initial Connections
window, select the parameter and click on the
Delete
button.
5. Decoder parameters cannot be edited. The only way to change a parameter is to delete the original as
described above, and recreate the parameter with the changed settings and selections and then click
on the
Add
button.
6. RFCOMM parameters are saved when the template is saved as described in
3.2.4.2 RFCOMM Missing Decode Information
ComProbe software usually determines the protocol carried in an RFCOMM payload by monitoring previous
traffic. However, when this fails to occur, the
Missing Decoding Information Detected
dialog appears
and requests that the user supply the missing information.
The following are the most common among the many possible reasons for a failure to determine the
traversal:
l
The capture session started after transmission of the vital information
l
The analyzer incorrectly received a frame with the traversal information
l
The communication monitored takes place between two players with implicit information not included in
the transmission
In any case, either view the RFCOMM payload of this frame (and other frames with the same channel) as hex
data, or assist the analyzer by selecting a protocol using this dialog.
Note that you may use the rest of the analyzer without addressing this dialog. Additional information gathered
during the capture session may help you decide how to respond to the request for decoding information.
If you are not sure of the payload carried by the subject frame, look at the raw data shown under
data
in the
Decode
pane in the
Frame Display
. You may notice something that hints as to the profile in use.
In addition, look at some of the frames following the one in question. The data may not be recognizable to the
analyzer at the current point due to connection setup, but might be discovered later on in the capture.
3.2.4.3 RFCOMM Override Decode Information
The
Set Subsequent Decoder Parameters
dialog allows the user to override an existing parameter at any
frame in the capture where the parameter is used.
If you have a parameter in effect and wish to change that parameter:
Chapter 3 Configuration Settings