Figure 4.29 - Frame Display Quick Filtering and Hiding Protocols Dialog
The box on the left is
Protocols To Filter In
. When you select the checkbox for a protocol in the
Protocols
to Filter In
, the
Summary
pane will only display those frames that contain data from that protocol.
If you filter on more than one protocol, the result are all frames that contain at least one
of those protocols. For example, if you filter on IP and IPX NetBIOS, you receive all frames
that contain either IP or IPX NetBIOS (or both). A
Quick Filter
tab then appears on the
Frame Display
. Changing the filter definition on the
Quick Filter
dialog changes the filter applied on the
Quick Filter
tab. Quick filters are persistent during the session, but are discarded when the session is closed.
The box in the center is the
Protocols To Hide
. When you select the checkbox for a protocol in the
Protocols To Hide
, data for that protocol will not appear in the
Decode
,
Binary
,
Radix
, and
Character
panes. The frames containing that type data will still appear in the
Summary
pane, but not in the
Decode
,
Binary
,
Radix
, and
Character
panes.
The box on the right is the
Named Filters
. It contains filters that you
create using the and dialogs. When you select the checkbox for the
Name Filters
, a tab appears on the Summary Pane that displays the
frame containing the specific data identified in the filter. The named
Filter tab remains on the Frame Display Summary Pane
unless you hide it using the dialog.
With low energy, the Configured BT Low energy devices
and Exclude NULLS and POLLs are default named filters.
Check the small box next to the name of each protocol you want to filter
in, hide, or
Named Filter
to display.
Then click
OK
4.3.1.13.3.2 Easy Protocol Filtering
There are two types of easy protocol filtering. The first method lets you filter on the protocol shown in the
Summary
pane, and the second lets you filter on any protocol discovered on the network so far.
Filtering on the Summary Layer Protocol
To filter on the protocol in the
Summary
in the
Frame Display
window pane:
1. Select the tab of the desired protocol, or open the
Summary
combo box.
2. Select the desired protocol.
3. To filter on a different layer, just select another tab, or change the layer selection in the combo box.
TELEDYNE LECROY
Chapter 4 Capturing and Analyzing Data
72
Frontline BPA low energy Hardware & Software User Manual