Figure 4.37 -
low energy Timeline
and
Frame Display
Packet Synchronization
4.3.2.10 low energy Timeline Visual Elements
The low energy Timeline consists of the following visual elements:
l
Time Markers - Time markers indicated by vertical blue lines are shown at 1.25 ms intervals. The markers
are provided to help visualize the timescale and are also useful when using dual-mode chips that do
BR/EDR and LE at the same time. Time markers snap to the beginning of the first data packet by default,
but they can be snapped to the beginning or end of any packet by right-clicking on a packet and selecting
Align Time Marker to Beginning of Packet
or
Align Time Marker to End of Packet
. All other
markers will shift relative to that new reference point.
Figure 4.38 - Timeline Markers Shown Snapped to End of Packet
l
Timestamp - The beginning and ending timestamp for each segment is displayed beneath each segment.
When showing multiple segments the beginning timestamp is the same as the ending timestamp of the
previous segment.
In addition to the timestamps the segment information bar shows the zoom value in the center of the bar.
TELEDYNE LECROY
Chapter 4 Capturing and Analyzing Data
84
Frontline BPA low energy Hardware & Software User Manual
Summary of Contents for BPA LOW ENERGY
Page 1: ...Hardware and Software User Manual Revision Date 1 3 2017...