Figure 4.18 - Save Named Filter Condition Dialog
The
Set Condition
dialog box closes, creates a tab on the
Frame Display
with the filter name, and applies
the filter.
When a display filter is applied, a description of the
filter appears to the right of the toolbar in the
Frame Display
windows.
Note:
The
OK
button on the
Set Condition
dialog box is unavailable (grayed out) until the
condition selections are complete.
4.3.1.13.1.5 Defining Node and Conversation Filters
There are two steps to using Node and Conversation display filter. Define the filter conditions, and then apply
the filter to the data set. The analyzer combines both filter definition and application in one dialog.
1. Click the
Display Filters
icon
on the
Frame Display
window or select
Apply/Modify
Display Filters…
from the filter menu to open the
Set Condition
dialog box.
2. From the
Select each frame
combo box choose
frames with the conversation
as the initial
condition.
3. Select an address type—IP, MAC, TCP/UDB—from the
Type
combo box (The address type selection
populates both Address combo boxes with node address in the data set that match the type selection).
4. Select a node address from the first
Address
combo box.
5. Choose a direction arrow from the direction box . The left arrow filters on all frames
where the top node address is the destination, the right arrow filters on all frames
where the top node address is the source, and the double arrow filters on all
frames where the top node address is either the source or the destination.
6. If you want to filter on just one node address, skip step 7 and continue with step 8.
7. If you want to filter on traffic going between two address nodes (i.e. a conversation), select a node
address from the second Address combo box..
8. Click
OK
. The
Set Condition
dialog box closes and the analyzer applies the filter.
When a display filter is applied, a description of the filter appears to the right of the toolbar in the
Frame
Display
windows.
Note:
The
OK
button is unavailable (grayed out) until the condition selections are
complete.
TELEDYNE LECROY
Chapter 4 Capturing and Analyzing Data
62
Frontline BPA low energy Hardware & Software User Manual