show eaps
ExtremeWare 7.7 Command Reference Guide
1479
Example
The following command displays detailed EAPS information for domain “eaps1”:
show eaps eaps1 detail
The results for domain “eaps1” on a master node are shown as follows:
Name: "eaps1" (instance=0)
State: Complete [Running: Yes]
Enabled: Yes Mode: Master
Primary port: 10 Port status: Up Tag status: Tagged
Secondary port: 20 Port status: Blocked Tag status: Tagged
Hello Timer interval: 1 sec Fail Timer interval: 3 sec
Fail timer expiry action: Send alert
Last update: From Master Id 00:04:96:18:40:92, at Wed Jan 28 15:58:20 2004
EAPS Domain has following Controller Vlan:
Vlan Name VID QosProfile
"cvlan" 0100 QP8
EAPS Domain has following Protected Vlan(s):
Vlan Name VID QosProfile
"pvlan" 0200 QP1
Number of Protected Vlans: 1
The following command displays detailed EAPS information:
show eaps detail
The results for a transit node are shown as follows:
EAPS Enabled: Yes
Number of EAPS instances: 1
EAPSD-Bridge links: 2
Name: “eaps1” (instance=0)
State: Links-Up [Running: Yes]
Enabled: Yes Mode: Transit
Primary port: 13 Port status: Up Tag status: Tagged
Secondary port: 14 Port status: Up Tag status: Tagged
Failtimer expiry action:
Displays the action taken when the failtimer expires:
•
Send-alert—Sends a critical message to the syslog when the failtimer
expires.
•
Open-secondary-port—Opens the secondary port when the failtimer expires.
Displays only for master nodes.
Preforwarding Timer interval:
1
The configured value of the timer. This value is set internally by the EAPS
software.
Last update:
1
Displayed only for transit nodes; indicates the last time the transit node
received a hello packet from the master node (identified by its MAC address).
EAPS Domain has … Controller
Vlans:
Lists the assigned name and ID of the control VLAN.
EAPS Domain has … Protected
Vlans:
2
Lists the assigned names and VLAN IDs of all the protected VLANs configured
on this EAPS domain.
Number of Protected Vlans:
The count of protected VLANs configured on this EAPS domain.
1.
These fields apply only to transit nodes; they are not displayed for a master node.
2.
This list is displayed when you use the
detail
keyword in the
show eaps
command.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...