configure slb node tcp-port-check
ExtremeWare 7.7 Command Reference Guide
555
configure slb node tcp-port-check
configure slb node <ip address>:[ftp | http | https | imap4 | ldap | nntp |
pop3 | smtp | socks | telnet | tftp | web | wildcard | www | <TCP or UDP
port number>] tcp-port-check frequency <seconds> timeout <seconds>
Description
Overrides the global default frequency and timeout values for this node.
Syntax Description
Default
The default frequency is 30 seconds.
The default timeout is 90 seconds.
Usage Guidelines
To set the global TCP port check frequency and timeout, use the following command:
configure slb global tcp-port-check
The frequency must be less than the timeout.
ip address
Specifies the IP address of the node.
ftp
Specifies the FTP TCP port check.
http
Specifies the HTTP TCP port check.
https
Specifies the HTTPS TCP port check.
imap4
Specifies the IMAP4 TCP port check.
ldap
Specifies the LDAP TCP port check.
nntp
Specifies the NNTP TCP port check.
pop3
Specifies the POP3 TCP port check.
smtp
Specifies the SMTP TCP port check.
socks
Specifies the SOCKS TCP port check.
telnet
Specifies the telnet TCP port check.
tftp
Specifies the TFTP TCP port check.
web
Specifies the Web TCP port check.
wildcard
Specifies any port associated with a wildcard server.
www
Specifies the www TCP port check.
TCP or UDP port number
Specifies a TCP or UDP port for the TCP port check.
frequency
Specifies the frequency of the TCP port check. The range is 5 to 120 seconds.
timeout
Specifies the timeout of the TCP port check. The range is 5 to 300 seconds.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...