create fdbentry vlan dynamic
ExtremeWare 7.7 Command Reference Guide
415
create fdbentry vlan dynamic
For
“i”
series switches:
create fdbentry [<mac_address> | broadcast-mac | any-mac] vlan <vlan name>
dynamic [qosprofile <qosprofile> {ingress-qosprofile <inqosprofile>} |
ingress-qosprofile <inqosprofile> {qosprofile <qosprofile>}]
For
“e”
series switches:
create fdbentry [<mac_address> | any-mac] vlan <vlan name> dynamic
[ingress-qosprofile <qosprofile> {ingress-qosprofile <inqosprofile>}]
Description
Creates a permanent dynamic FDB entry, and associates it with an ingress and/or egress QoS profile.
Syntax Description
Default
N/A
Usage Guidelines
This command is used to associate QoS profiles with packets received from or destined for the specified
MAC address, while still allowing the FDB entry to be dynamically learned.
The FDB entry is not actually created until the MAC address is encountered as the source MAC address
in a packet. Thus, initially the entry may not appear in the
show fdb
output. Once the entry has been
learned, it is created as a permanent dynamic entry, designated by “dpm” in the flags field of the
show
fdb
output.
A dynamic entry is flushed and relearned (updated) when any of the following take place:
•
A VLAN is deleted.
•
A VLAN identifier (VLANid) is changed.
•
A port mode is changed (tagged/untagged).
•
A port is deleted from a VLAN.
mac_address
Specifies a device MAC address, using colon separated bytes.
broadcast-mac
Specifies the broadcast MAC address. May be used as an alternate to the colon-separated
byte form of the address ff:ff:ff:ff:ff:ff.
NOTE: This option is only available on the “i” series of switches.
any-mac
Specifies the wildcard, permanent FDB entry used to give higher priority to an 802.1p packet.
vlan name
Specifies a VLAN name associated with a MAC address.
dynamic
Specifies that the entry will be learned dynamically.
qosprofile
QoS profile associated with the destination MAC address of the egress port.
inqosprofile
QoS profile associated with the source MAC address of the ingress port.
NOTE: This option is only available on the “i” series of switches.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...