1450
ExtremeWare 7.7 Command Reference Guide
Stacking Commands
Example
The following command displays all the information in the stacking database:
show stacking
Output from the command is similar to:
Stacking Data Base
==================
Common Info
Mode : Dup-No-Ring State : Up-Master Stacking : Enabled
Master Slot: 5 Switches: 8 Local Slot: 5
Config Slot: None Next Potential Master Slot : 4
Slot 1: State SLAVE
Status : Enabled Master : No MAC : 00:04:96:18:41:35
Binding : Active Cpu Pri : 0 Platform : S300-24
Slot-Mac : Loose Cfg Pri : 0 Cfg Slot : None
Stacking Ports: 2
Port-1 *1:25
Port-2 *1:26
Slot 2: State SLAVE
Status : Enabled Master : No MAC : 00:04:96:1F:1F:F5
Binding : Active Cpu Pri : 0 Platform : S200-48
Slot-Mac : Loose Cfg Pri : 0 Cfg Slot : None
Stacking Ports: 2
Port-1 *2:49
Port-2 *2:50
Slot 3: State SLAVE
Status : Enabled Master : No MAC : 00:04:96:1F:88:5A
Binding : Active Cpu Pri : 0 Platform : S300-24
Slot-Mac : Loose Cfg Pri : 0 Cfg Slot : None
Stacking Ports: 2
Port-1 *3:25
Port-2 *3:26
Slot 4: State SLAVE
Status : Enabled Master : No MAC : 00:04:96:05:7D:06
Binding : Active Cpu Pri : 0 Platform : S200-24
Slot-Mac : Loose Cfg Pri : 0 Cfg Slot : None
Stacking Ports: 2
Port-1 *4:25
Binding
Indicates the slot binding and whether it is active or inactive. Slot binding is inactive until the
switch joins the stack.
CPU Pri
Indicates the configured priority of the switch. The higher the number, the higher the priority.
Platform
Indicates the platform type.
Slot-Mac
Indicates the type of slot-mac binding. Values are: Loose, Strict.
Cfg Pri
Indicates the priority configured for the slot to become the master.
Cfg Slot
Indicates the configured slot number.
Stacking Ports
Indicates the stacking ports configured for the switch. An asterisk “*” indicates that the port is
enabled (not link status) and an exclamation point “!” indicates that the port is disabled for
stacking.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...