2562
ExtremeWare 7.7 Command Reference Guide
MPLS Commands—BlackDiamond Switch Only
configure mpls vpls add peer
config mpls vpls <vpls_name> add peer [<ipaddress> | <host_name>]
[core-to-core | spoke-to-core {primary | secondary} | core-to-spoke {vpls |
tls {vcid <vcid>} {dot1q ethertype <hex_number>}] {lsp <lsp_name>}
Description
Configures a VPLS peer for the specified vpls_name.
Syntax Description
Default
N/A
Usage Guidelines
This command configures a VPLS peer for the specified vpls_name. Up to 32 peers may be configured
for each VPLS. Peers may belong to multiple VPLS instances. The
ipaddress
parameter identifies the
peer node that is the endpoint of the VC-LSP. The ipaddress should be configured with a 32-bit prefix
on the peer node. When the peer node is also an Extreme switch, then either OSPF/ISIS must also be
enabled on the VLAN that the ipaddress is assigned, or the peer switch must be configured to distribute
direct routes into the OSPF/ISIS domain. Note that the export command should be used when the
tunnel LSP needs to cross OSPF area boundaries or when ESRP is enabled on the VLAN that the
ipaddress is assigned. If the VPLS peer is specified using the
host_name
parameter, the DNS client
must be configured so that the host_name can first be resolved to an IP address.
Per node, each peer relationship for each VPLS must be configured. The peer relationships are defined
as either a core-to-core, core-to-spoke, or spoke-to-core. This relationship implicitly defines the packet
flooding behavior for the VC-LSP set up to the configured peer.
A VPLS peer relationship defined as
core-to-core
indicates that the peer is a member of a fully
meshed VPLS core peer group. Flood traffic received from a core node by the core node is forwarded to
spoke nodes only.
A VPLS peer relationship defined as
spoke-to-core
specifies the spoke connectivity from a spoke
node to a core node. Flood traffic received by a spoke node from a core node is forwarded to the local
egress interface. The
spoke-to-core
keyword may optionally be qualified with the redundant
configuration mode. The core node is either the primary or secondary VPLS peer. One primary core
vpls_name
Identifies the VPLS within the switch (character string)
ipaddress
Specifies the IP address for the peer node that is the endpoint of the VC-LSP
host_name
Specifies the peer host name.
core-to-core
Specifies the VPLS peer relationship which represents a member of a fully
meshed VPLS core peer group.
spoke-to-core
Specifies the spoke connectivity from a spoke node to a core node.
core-to-spoke
Specifies the spoke connectivity from the core node to the spoke node.
vcid
Specifies an option for VC-LSP between the core and spoke.
tps
Specifies an option for VC-LSP between the core and spoke.
hex_number
Specifies the ethertype for dot1q
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...