2324
ExtremeWare 7.7 Command Reference Guide
PoS Commands—BlackDiamond Switch Only
configure sonet trace section ports
configure sonet trace section [<id_byte> | string <id_string>]
ports <portlist>
Description
Configures the section trace identifier for the specified SONET ports.
Syntax Description
Default
The default is 1 for SONET, null for SDH.
Usage Guidelines
Section trace is a maintenance feature of SONET. One byte of the section overhead associated with each
SONET frame is used to carry information identifying the transmitting equipment. The section trace
identifier has two forms: an
id_byte
and an
id_string
. The
id_byte
parameter is an integer in the
range [0-255], with a default value of 1. The
id_string
parameter is a string that may contain up to 15
characters. By default,
id_string
contains 15 NULL characters. The
id_byte
parameter is only
applicable when SONET framing is configured. In this case, the configured
id_byte
value is
transmitted in each SONET frame. Analogously, the
id_string
parameter is only applicable when SDH
framing is configured. SDH framing repetitively cycles through a 15-character string, sending one
character per frame. If the configured string is less than 15 characters, it is padded with NULL
characters.
Example
The following command example sets the section trace identifier to the string
1800wombat
for port 1 of
the PoS module installed in slot 8 of the BlackDiamond switch:
config sonet trace section string 1800wombat ports 8:1
History
This command was first available in an ExtremeWare IP Technology Services Release based on
v6.1.5b20.
Platform Availability
This command is available on the BlackDiamond switch only.
id_byte
Configures the ID byte section trace identifier for the specified SONET port.
id_string
Configures the ID string section trace identifier for the specified SONET port.
portlist
Specifies the port number(s).
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...