configure sflow backoff-threshold
ExtremeWare 7.7 Command Reference Guide
707
configure sflow backoff-threshold
configure sflow backoff-threshold <rate>
Description
Configures the maximum number of packets sent to the sFlow collector per second.
NOTE
This command is available only on the “i” series switches.
Syntax Description
Default
The default is 50.
Usage Guidelines
This command configures the maximum number of samples sent to the CPU per second. If this rate is
exceeded, the internal sFlow CPU throttling mechanism kicks in to limit the load on the CPU. Each time
the limit is reached, the sample rate is halved (the value of number in the
configure sflow
sample-rate
or
configure sflow ports <portlist> sample-frequency <number>
command is
doubled) on the slot on which maximum number of packets are received.
This effectively doubles the sampling frequency of all the ports on that slot with a sub-sampling factor
of 1. The sampling frequency of ports on that slot with a sub-sampling factor greater than 1 will not
change; the sub-sampling factor is halved so that the same sample rate applies to that port.
Use the following command to reset the sFlow backoff threshold value to 0 (zero):
unconfigure sflow backoff-threshold
Example
The following command specifies that the sFlow backoff threshold should be set to a maximum of 256
packets per second:
configure sflow backoff-threshold 256
If the number of packets sent to the sFlow collector exceeds a rate of 256 packets per second, the
sampling rate is doubled. For example, if a sampling rate of 512 is exceeded, the sampling rate is
doubled to 1024.
History
This command was first available in ExtremeWare 7.3.0.
rate
Specifies the maximum number of packets sent to the sFlow collector per second. The range is 100 -
5000
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...