configure eaps failtime expiry-action
ExtremeWare 7.7 Command Reference Guide
1461
configure eaps failtime expiry-action
configure eaps <name> failtime expiry-action [ open-secondary-port |
send-alert]
Description
Configures the action taken when the failtimer expires.
Syntax Description
Default
Default is send-alert.
Usage Guidelines
In earlier releases of ExtremeWare, when the failtimer of a master node expired, the default action was
to open the secondary port. If the master node loses three Hello-PDUs in a row, the failtimer will expire,
but there might not necessarily be a break in the ring. Opening the secondary port in this situation
would create a loop.
The
configure eaps failtime expiry-action
command allows you to configure the action taken
when the failtimer expires.
By default the action is to send an alert if the failtimer expires. Instead of going into a “Failed” state, the
master node remains in a “Complete” or “Init” state, maintains the secondary port blocking, and writes
a critical error message to syslog warning the user that there is a fault in the ring. An SNMP trap is also
sent.
To use the failtimer expiry action of earlier releases, use the
open-secondary-port
parameter.
NOTE
You must explicitly configure the failtimer expiry action to
open-secondary-port
if the EAPS ring
includes a section composed of non-EAPS devices.
NOTE
If you have a previous release of ExtremeWare and are upgrading to ExtremeWare 7.1, or later, the
failtimer expiry action will default to
send-alert
.
name
Specifies the name of an EAPS domain.
open-secondary-port
Specifies to open the secondary port when the failtimer expires.
send-alert
Specifies that a critical message is sent to the syslog when the failtimer expires.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...