PowerPlay

 

Programming

 

Manual

 

HTTP

 

command

 

protocols

 

Connect

 

a

 

Cat5/6

 

cable

 

to

 

the

 

Ethernet

 

port

 

on

 

the

 

backpanel

 

of

 

the

 

PowerPlay

 

to

 

a

 

network

 

port.

  

The

 

PowerPlay

 

can

 

communicate

 

with

 

a

 

computer

 

connected

 

to

 

the

 

internet,

 

or

 

to

 

the

 

PS

 

Audio

 

Globalnet

 

Server.

   

HTTP

 

commands

 

are

 

entered

 

in

 

the

 

following

 

syntax:

 

http://

HOSTNAME

/commands.cgi?command=

XX

=

YYY

  

where

 

the

 

XX=YYY

 

portion

 

is

 

as

 

described

 

in

 

the

 

tables

 

below.

  

These

 

command

 

input

 

characters

 

must

 

be

 

uppercase.

  

HOSTNAME

 

can

 

be

 

the

 

host

 

name

 

of

 

the

 

PowerPlay

 

(readable

 

from

 

the

 

front

 

panel

 

display,

 

or

 

network

 

interface),

 

or

 

the

 

IP

 

address

 

(also

 

readable

 

from

 

the

 

front

 

panel

 

display,

 

or

 

network

 

interface).

 

If

 

there

 

is

 

a

 

command

 

input

 

error,

 

depending

 

on

 

the

 

type

 

of

 

error,

 

the

 

PowerPlay

 

will

 

respond

 

with

 

either

    

&data=OK,

 

or

   

&data=ERROR.

 

Serial

 

command

 

protocols

 

Connect

 

a

 

terminal

 

or

 

computer

 

directly

 

to

 

the

 

female

 

DB9

 

RS232

 

connector

 

on

 

the

 

PowerPlay

 

backpanel

 

for

 

direct

 

serial

 

communication.

  

Port

 

setup

 

parameters:

 

 

Baud

 

rate

 

19200

 

 

No.

 

of

 

data

 

bits

 

8

 

 

No.

 

of

 

stop

 

bits

 

1

 

 

Parity

   

none

 

 

Flow

 

control

 

none

 

Serial

 

commands

 

are

 

entered

 

in

 

the

 

following

 

syntax:

 

XX=YYY

\n\r

  

where

 

XX=YYY

 

is

 

as

 

described

 

in

 

the

 

tables

 

below.

  

The

 

\n\r

 

command

 

terminators

 

are

 

new

 

line

 

and

 

carriage

 

return.

 

If

 

there

 

is

 

a

 

command

 

input

 

error,

 

depending

 

on

 

the

 

type

 

of

 

error,

 

the

 

PowerPlay

 

will

 

respond

 

with

 

either

    

&data=OK,

 

or

   

&data=ERROR

 

 

 

Summary of Contents for PowerPlay

Page 1: ...rk interface or the IP address also readable from the front panel display or network interface If there is a command input error depending on the type of error the PowerPlay will respond with either data OK or data ERROR Serial command protocols Connect a terminal or computer directly to the female DB9 RS232 connector on the PowerPlay backpanel for direct serial communication Port setup parameters...

Page 2: ...F UB OFF data OK Display brightness status UB data xxx BRIGHT DIM OR OFF Output Delay Set Unit output ON OFF delay seconds UD x y up to 65536 65536 data OK Return output delay settings UD data x y x number of seconds of delay before switching on y number of seconds before switching off Unit Lockout Turn front panel lockout OFF UL OFF data OK Turn front panel lockout ON UL ON data OK Return Lockout...

Page 3: ...one Delay to Delayed ZD x DLY data OK Set Specified Zone Delay to Programmed ZD x PGM data OK Set Specified Zone Delay to Reboot ZD x RBT data OK Set Specified Zone Delay to Auto Reboot ZD x ARB data OK Return Specified Zone Delay Status ZD x data yyy ON SW DLY PGM RBT OR ARB Set Specified Zone Delay Time seconds ZT x y z up to 65536 65536 data OK Return Specified Zone Delay Time ZT x data y z y n...

Page 4: ...111111111 volts 122 watts 10 thd 3 3 temp nosensor ups notfound Response Range of Response Unit Power Status upwr 0 if off 1 if on Over Voltage Metal Oxide Varistor MOV Protection Status umov 0 if no MOV protection 1 if MOVs are ok Zone Power Status zpwr For each zone 0 if off 1 if on Output Voltage volts Same as the output voltage displayed on the front panel Output Power watts Same as the output...

Page 5: ...r ups notfound dhcps 1 d hcp 1 mac 001FF6000081 ip 192 168 249 51 mask 255 255 255 0 gateway 192 168 249 1 pdns 192 168 249 204 sdns 192 168 249 206 hostname PowerPlay1 fwvproc 2 01 fwvboot 1 05 fwvw eb 1 11 fwvtel 1 01 fwvtelwav 1 04 RA Response Range of Response Unit Power Status upwr 0 if off 1 if on Unit Name uname Up to 16 alphanumeric characters Unit Time Delay On utdon 0 to 65536 Unit Time ...

Page 6: ...r Hostname hostname Up to 16 alphanumeric characters Processor Firmware Version fwvproc Version number of main control software Bootloader Firmware Version fwvboot Version number of bootloader software Web Firmware Version fwvweb Version number of Web interface software Telephone control Firmware Version fwvtel Version number of phone control software Telephone control wav file Fimware fwvtelwav V...

Reviews: