15
‐
052
‐
99
‐
1
‐
DOM
‐
A
Page3
of
6
Table
2:
Zone
Commands
Command
Action
Syntax
(x=zone
number
1
‐
10)
PowerPlay
Response
Zone
Power
Turn
Specified
Zone
Off
ZP=x,OFF
&data=OK
Turn
Specified
Zone
On
ZP=x,ON
&data=OK
Reboot
Specified
Zone
ZP=x,REBOOT
&data=OK
Return
Specified
Zone
Power
Status
ZP=x,?
&data=yyy
(ON
or
OFF)
Zone
Name
Set
specified
Zone
Name
ZN=x,
y
(up
to
16
chars)
&data=OK
Return
Specified
Zone
Name
ZN=x,?
&data=yyy
(Zone
Name
Characters)
Zone
Delay
Set
Specified
Zone
Delay
to
Always
On
ZD=x,ON
&data=OK
Set
Specified
Zone
Delay
to
Switched
ZD=x,SW
&data=OK
Set
Specified
Zone
Delay
to
Delayed
ZD=x,DLY
&data=OK
Set
Specified
Zone
Delay
to
Programmed
ZD=x,PGM
&data=OK
Set
Specified
Zone
Delay
to
Reboot
ZD=x,RBT
&data=OK
Set
Specified
Zone
Delay
to
Auto
‐
Reboot
ZD=x,ARB
&data=OK
Return
Specified
Zone
Delay
Status
ZD=x,?
&data=yyy
(ON,SW,DLY,
PGM,RBT,
OR
ARB)
Set
Specified
Zone
Delay
Time
(seconds)
ZT=x,y,z
(up
to
65536,65536)
&data=OK
Return
Specified
Zone
Delay
Time
ZT=x,?
&data=y,z
(y=
number
of
seconds
of
delay
before
switching
on.
z=
number
of
seconds
before
switching
off
Zone
Priority
Set
Specified
Zone
Priority
Level
to
Low
ZL=x,LOW
&data=OK
Set
Specified
Zone
Priority
Level
to
Normal
ZL=x,NORMAL
&data=OK
Set
Specified
Zone
Priority
Level
to
Critical
ZL=x,CRITICAL
&data=OK
Return
Specified
Zone
Priority
Level
ZL=x,?
&data=yyy
(LOW,
NORMAL,
or
CRITICAL)