Maintenance schedule
201
4812313240.pdf
2017-12-1
Maintenance
1 Notes
regarding
safety
for
maintenance
During all maintenance work, the regulations regarding health, work and fire
protection are to be heeded. The necessary protective equipment is to be worn
continuously.
If not described otherwise, maintenance work must only be carried out with the
engine stopped (heed the notes regarding checking and replacing milling bits
and milling bit holders!).
Maintenance work must only be carried out on even and stable surfaces.
When working in closed areas, exhaust fumes must be vented to the outside.
Provide sufficient ventilation.
Before beginning maintenance work, secure the machine against inadvertent
starting, rolling away or lowering by:
- putting the drive lever into the neutral central position and putting the
machine feed into the “zero” position using the selection switch.
- removing the ignition key and the main switch
- positioning the sign “DO NOT START” on the control panel so that it is
clearly visible.
- when working under the machine, position all traction unit supports and
wear a hardhat.
- If required, use chocks to prevent the drive units from rolling away.
In addition, pay attention to the following when replacing the milling bit and the
milling bit holder.
- if the pneumatic bit extractor is used, the drive engine must only run at
idling speed. The milling drum drive must be switched off.
- The drum flap is locked in the open position.
- The limit switch of the drum flap is functioning.
- The belt tightened must be retracted and the clutch must be deactivated.
If safety and protective devices must be removed for maintenance, they must
be properly reinstalled again before putting the machine back into operation.
Do not use easily flammable materials during cleaning.
Always keep steps and other areas where persons can stand free of lubricants
and slip-proof.
When using the installed high-pressure cleaner or a stem sprayer to hose
down electric parts, do not expose any electronic modules, insulators or
ventilators to the direct water jet; cover these items if possible.
Summary of Contents for PL2000F
Page 2: ......
Page 15: ...Introduction 4 4812313240 pdf 2017 12 1...
Page 29: ...Safety General instructions 18 4812313240 pdf 2017 12 1...
Page 33: ...Special instructions 22 4812313240 pdf 2017 12 1...
Page 35: ...Technical specifications 24 4812313240 pdf 2017 12 1 Dimensions...
Page 41: ...Technical specifications 30 4812313240 pdf 2017 12 1...
Page 56: ...Machine description 45 4812313240 pdf 2017 12 1 Decals...
Page 57: ...Machine description 46 4812313240 pdf 2017 12 1...
Page 58: ...Machine description 47 4812313240 pdf 2017 12 1...
Page 66: ...Machine description 55 4812313240 pdf 2017 12 1 Switch panel Main console left right...
Page 68: ...Machine description 57 4812313240 pdf 2017 12 1...
Page 70: ...Machine description 59 4812313240 pdf 2017 12 1...
Page 72: ...Machine description 61 4812313240 pdf 2017 12 1...
Page 74: ...Machine description 63 4812313240 pdf 2017 12 1...
Page 76: ...Machine description 65 4812313240 pdf 2017 12 1...
Page 78: ...Machine description 67 4812313240 pdf 2017 12 1...
Page 80: ...Machine description 69 4812313240 pdf 2017 12 1 Control lever panel...
Page 82: ...Machine description 71 4812313240 pdf 2017 12 1 LH RH Ergo control...
Page 92: ...Machine description 81 4812313240 pdf 2017 12 1...
Page 173: ...Machine description 162 4812313240 pdf 2017 12 1...
Page 190: ...Miscellaneous 179 4812313240 pdf 2017 12 1 Fix points Fig Fix points...
Page 207: ...Operating instructions 196 4812313240 pdf 2017 12 1...
Page 209: ...Preventive maintenance 198 4812313240 pdf 2017 12 1...
Page 211: ...Maintenance Lubricants and symbols 200 4812313240 pdf 2017 12 1...