Option
Name
Description
[37]
Set digital out F low
[38]
Set digital out A high
[39]
Set digital out B high
[40]
Set digital out C high
[41]
Set digital out D high
[42]
Set digital out E high
[43]
Set digital out F high
[60]
Reset counter A
[61]
Reset counter B
[62]
Counter A (up)
[63]
Counter A (down)
[64]
Counter B (up)
[65]
Counter B (down)
Parameter 23-02 OFF Time
Table 680: Parameter 23-02 OFF Time
23-02 OFF Time
Default Value: Size related
Parameter Type: Range, 0 - 0
Setup: 2 set-ups
Conversion Index: 0
Data Type: TimeOfDayWoDate
Change during operation: True
Sets the OFF time for the desired action.
N O T I C E
The drive has no back-up of the clock function. The set date/time resets to default (2000-01-01 00:00) after a power-down unless
a real-time clockmodule with back-up is installed. In
parameter 0-79 Clock Fault
, it is possible to program a warning if the clock has
not been set properly, for example after a power-down.
Parameter 23-03 OFF Action
Table 681: Parameter 23-03 OFF Action
23-03 OFF Action
Default Value: [1] No action
Parameter Type: Option, Array [10]
Setup: 2 set-ups
Conversion Index: -
Data Type: Uint8
Change during operation: True
Select the action during OFF time. See
parameter 13-52 SL Controller Action
for descriptions of the options.
Option
Name
Description
[1]*
No action
[2]
Select set-up 1
[3]
Select set-up 2
AU373327181955en-000101 / 130R1208 | 325
Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide