Option
Name
Description
[0]*
FC
[1]
FC MC
[2]
Modbus RTU
Parameter 8-31 Address
Table 423: Parameter 8-31 Address
8-31 Address
Default value: 1
Parameter type: Range, 1 - 247
Setup: 1 setup
Conversion index: 0
Data type: Uint8
Change during operation: True
Enter the address for the drive (standard) port. Valid range: Depends on the selected protocol.
Parameter 8-32 FC Port Baud Rate
Table 424: Parameter 8-32 FC Port Baud Rate
8-32 FC Port Baud Rate
Default value: Size related
Parameter type: Option
Setup: 1 setup
Conversion index: –
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]
2400 Baud
Baud rate selection for the FC (standard) port.
[1]
4800 Baud
[2]
9600 Baud
[3]
19200 Baud
[4]
38400 Baud
[5]
57600 Baud
[6]
76800 Baud
[7]
115200 Baud
Parameter 8-33 Parity/Stop Bits
Table 425: Parameter 8-33 Parity/Stop Bits
8-33 Parity/Stop Bits
Default value: [0] Even parity, 1 stop bit
Parameter type: Option
Setup: 1 setup
Conversion index: –
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Even parity, 1 stop bit
[1]
Odd parity, 1 stop bit
[2]
No parity, 1 stop bit
[3]
No parity, 2 stop bits
AU373327181955en-000101 / 130R1208
214 | Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide