Parameter 0-32 Max Value of User-defined Readout
Table 25: Parameter 0-32 Max Value of User-defined Readout
0-32 Max Value of User-defined Readout
Default value: 100 CustomReadoutUnit Parameter type: Range [par. 0-31 -999999.99 Custom-
ReadoutUnit]
Setup: All setups
Conversion index: -2
Data type: Int32
Change during operation: True
This parameter sets the maximum value to be shown when the speed of the motor has reached the set value for
parameter 4-13
Motor Speed High Limit [RPM]
or
parameter 4-14 Motor Speed High Limit [Hz]
(depends on setting in
parameter 0-02 Motor Speed Unit
).
Parameter 0-33 Source for User-defined Redaout
Table 26: Parameter 0-33 Source of User-defined Readout
0-33 Source of User-defined Readout
Default value: [240] Default Source
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Enter the source of the user-defined readout.
Option
Name
Description
[105]
Torque relate to rated
[143]
PID Clamped Output 4–20mA
[240]*
Default Source
Parameter 0-37 Display Text 1
Table 27: Parameter 0-37 Display Text 1
0-37 Display Text 1
Default value: 0
Parameter type: Range [0–25]
Setup: 1 setup
Conversion index: 0
Data type: VisStr[25]
Change during operation: True
Enter a text which can be viewed in the graphical display by selecting
[37] Display Text 1
in
Parameter 0-20 Display Line 1 Small
Parameter 0-21 Display Line 1.2 Small
Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large
Parameter 0-38 Display Text 2
Table 28: Parameter 0-38 Display Text 2
0-38 Display Text 2
Default value: 0
Parameter type: Range [0–25]
Setup: 1 setup
Conversion index: 0
Data type: VisStr[25]
Change during operation: True
Enter a text which can be viewed in the graphical display by selecting
[38] Display Text 2
in
Parameter 0-20 Display Line 1 Small
Parameter 0-21 Display Line 1.2 Small