Parameter 15-11 Logging Interval
Table 530: Parameter 15-11 Logging Interval
15-11 Logging Interval
Default Value: Size related
Parameter Type: Range, 0.000 - 0.000
Setup: 2 set-ups
Conversion Index: -3
Data Type: Time diff wo DateID [4]
Change during operation: True
Enter the interval in ms between each sampling of the variables to be logged.
Parameter 15-12 Trigger Event
Table 531: Parameter 15-12 Trigger Event
15-12 Trigger Event
Default Value: [0] False
Parameter Type: Option
Setup: 1 set-up
Conversion Index: -
Data Type: Uint8
Change during operation: True
Select the trigger event. When the trigger event occurs, a window is applied to freeze the log. The log then retains a specified per-
centage of samples before the occurrence of the trigger event (
parameter 15-14 Samples Before Trigger
).
Option
Name
Description
[0]*
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low