Parameter 30-11 Wobble Random Ratio Max.
Table 703: Parameter 30-11 Wobble Random Ratio Max.
30-11 Wobble Random Ratio Max.
Default Value: 10
Parameter Type: Range, par. 17-53 - 10
Setup: All set-ups
Conversion Index: -1
Data Type: Uint8
Change during operation: True
Enter the maximum allowed wobble ratio.
Parameter 30-12 Wobble Random Ratio Min.
Table 704: Parameter 30-12 Wobble Random Ratio Min.
30-12 Wobble Random Ratio Min.
Default Value: 0.1
Parameter Type: Range, 0.1 - par. 30-11
Setup: All set-ups
Conversion Index: -1
Data Type: Uint8
Change during operation: True
Enter the minimum allowed wobble ratio.
Parameter 30-19 Wobble Delta Freq. Scaled
Table 705: Parameter 30-19 Wobble Delta Freq. Scaled
30-19 Wobble Delta Freq. Scaled
Default Value: 0 Hz
Parameter Type: Range, 0 - 1000 Hz
Setup: All set-ups
Conversion Index: -1
Data Type: Uint16
Change during operation: False
Readout parameter. View the actual wobble delta frequency after scaling has been applied.
4.20.2 30-2* Adv. Start Adjust
Parameter 30-20 High Starting Torque Time [s]
Table 706: Parameter 30-20 High Starting Torque Time [s]
30-20 High Starting Torque Time [s]
Default Value: Size related
Parameter Type: Range, 0 - 60 s
Setup: All set-ups
Conversion Index: -2
Data Type: Uint16
Change during operation: True
High starting torque time for PM motor in flux control principle without feedback.
Parameter 30-21 High Starting Torque Current [%]
Table 707: Parameter 30-21 High Starting Torque Current [%]
30-21 High Starting Torque Current [%]
Default Value: Size related
Parameter Type: Range, 0 - 200.0%
Setup: All set-ups
Conversion Index: -1
Data Type: Uint32
Change during operation: True
High starting torque current for PM motor in VVC
+
and flux mode without feedback.
Parameter 30-22 Locked Rotor Protection
Table 708: Parameter 30-22 Locked Rotor Protection
30-22 Locked Rotor Protection
Default Value: Size related
Parameter Type: Option
Setup: All set-ups
Conversion Index: -
Data Type: Uint8
Change during operation: True
AU373327181955en-000101 / 130R1208 | 337
Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide