Digital input function
Select
Terminal
Jog
[14]
All, terminal 29
Preset reference on
[15]
All
Preset ref bit 0
[16]
All
Preset ref bit 1
[17]
All
Preset ref bit 2
[18]
All
Freeze reference
[19]
All
Freeze output
[20]
All
Speed up
[21]
All
Speed down
[22]
All
Set-up select bit 0
[23]
All
Set-up select bit 1
[24]
All
Precise stop inverse
[26]
18, 19
Precise start, stop
[27]
18, 19
Catch up
[28]
All
Slow down
[29]
All
Counter input
[30]
29, 33
Pulse input edge triggered
[31]
29, 33
Pulse input time based
[32]
29, 33
Ramp bit 0
[34]
All
Ramp bit 1
[35]
All
Latched precise start
[40]
18, 19
Latched precise stop inverse
[41]
18, 19
External interlock
[51]
–
DigiPot increase
[55]
All
DigiPot decrease
[56]
All
DigiPot clear
[57]
All
DigiPot hoist
[58]
All
Counter A (up)
[60]
29, 33
Counter A (down)
[61]
29, 33
Reset Counter A
[62]
All
Counter B (up)
[63]
29, 33
Counter B (down)
[64]
29, 33
AU373327181955en-000101 / 130R1208 | 143
Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide