Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large
Parameter 0-39 Display Text 3
Table 29: Parameter 0-39 Display Text 3
0-39 Display Text 3
Default value: 0
Parameter type: Range [0–25]
Setup: 1 setup
Conversion index: 0
Data type: VisStr[25]
Change during operation: True
Enter a text which can be viewed in the graphical display by selecting
[39] Display Text 3
in
Parameter 0-20 Display Line 1 Small
Parameter 0-21 Display Line 1.2 Small
Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large
4.1.5 0-4* LCP Keypad
Enable, disable, and password protect individual keys on the LCP.
Parameter 0-40 [Hand On] Key on LCP
Table 30: Parameter 0-40 [Hand On] Key on LCP
0-40 [Hand On] Key on LCP
Default value: Size related
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Option Name
Description
[0]
Disabled
No effect when [Hand On] is pressed. Select
[0] Disabled
to avoid accidental start of the drive in
hand-on mode.
[1]
Enabled
The LCP switches to hand-on mode directly when [Hand On] is pressed.
[2]
Password
After pressing [Hand On] a password is required. If
parameter 0-40 [Hand on] Key on LCP
is included
in
My Personal Menu
, define the password in
parameter 0-65 Personal Menu Password
. Otherwise
define the password in
parameter 0-60 Main Menu Password
.
[3]
Hand Off/On
When [Hand On] is pressed once, the LCP switches to Off mode. When pressed again, the LCP
switches to hand-on mode.
[4]
Hand Off/On w.
Passw.
Same as option
[3] Hand Off/On
but a password is required (see option
[2] Password
).
[9]
Enabled, ref=0
Parameter 0-41 [Off] Key on LCP
Table 31: Parameter 0-41 [Off] Key on LCP
0-41 [Off] Key on LCP
Default value: Size related
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
AU373327181955en-000101 / 130R1208
48 | Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide