Option
Function
[54]
24V encoder sim
Digital outputs 27 and 29 simulate a single-signal HTL encoder. Select source for the signal gener-
ation in
parameter 5-78 Term 27/29 Encoder Sim
.
[55]
Pulse output
[58]
Actual position
[59]
Actual position 4–
20 mA
[60]
Comparator 0
See
parameter group 13-1* Comparators
. If comparator 0 is evaluated as true, the output goes
high. Otherwise, it is low.
[61]
Comparator 1
See
parameter group 13-1* Comparators
. If comparator 1 is evaluated as true, the output goes
high. Otherwise, it is low.
[62]
Comparator 2
See
parameter group 13-1* Comparators
. If comparator 2 is evaluated as true, the output goes
high. Otherwise, it is low.
[63]
Comparator 3
See
parameter group 13-1* Comparators
. If comparator 3 is evaluated as true, the output goes
high. Otherwise, it is low.
[64]
Comparator 4
See
parameter group 13-1* Comparators
. If comparator 4 is evaluated as true, the output goes
high. Otherwise, it is low.
[65]
Comparator 5
See
parameter group 13-1* Comparators
. If comparator 5 is evaluated as true, the output goes
high. Otherwise, it is low.
[70]
Logic rule 0
See
parameter group 13-4* Logic Rules
. If logic rule 0 is evaluated as true, the output goes high.
Otherwise, it is low.
[71]
Logic Rule 1
See
parameter group 13-4* Logic Rules
. If logic rule 1 is evaluated as true, the output goes high.
Otherwise, it is low.
[72]
Logic Rule 2
See
parameter group 13-4* Logic Rules
. If logic rule 2 is evaluated as true, the output goes high.
Otherwise, it is low.
[73]
Logic rule 3
See
parameter group 13-4* Logic Rules
. If logic rule 3 is evaluated as true, the output goes high.
Otherwise, it is low.
[74]
Logic rule 4
See
parameter group 13-4* Logic Rules
. If logic rule 4 is evaluated as true, the output goes high.
Otherwise, it is low.
[75]
Logic rule 5
See
parameter group 13-4* Logic Rules
. If logic rule 5 is evaluated as true, the output goes high.
Otherwise, it is low.
[80]
SL digital output A
See
parameter 13-52 SL Controller Action
. The output goes high whenever the smart logic action
[38] Set dig. out. A high
is executed. The output goes low whenever the smart logic action
[32] Set
dig. out. A low
is executed.
[81]
SL digital output B
See
parameter 13-52 SL Controller Action
. The output goes high whenever the smart logic action
[39] Set dig. out. B high
is executed. The output goes low whenever the smart logic action
[33] Set
dig. out. B low
is executed.
[82]
SL digital output C
See
parameter 13-52 SL Controller Action
. The output goes high whenever the smart logic action
[40] Set dig. out. C high
is executed. The output goes low whenever the smart logic action
[34] Set
dig. out. C low
is executed.
[83]
SL digital output D
See
parameter 13-52 SL Controller Action
. The output goes high whenever the smart logic action
[41] Set dig. out. D high
is executed. The output goes low whenever the smart logic action
[35] Set
dig. out. D low
is executed.
AU373327181955en-000101 / 130R1208 | 159
Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide