Option
Function
[189] External fan control
The internal logics for the internal fan control is transferred to this output to make it possible to
control an external fan (relevant for hp duct cooling).
[190] Safe function active
[191] Safe opt. reset req.
[192] RS Flipflop 0
See
parameter group 13-1* Comparators
.
[193] RS Flipflop 1
See
parameter group 13-1* Comparators
.
[194] RS Flipflop 2
See
parameter group 13-1* Comparators
.
[195] RS Flipflop 3
See
parameter group 13-1* Comparators
.
[196] RS Flipflop 4
See
parameter group 13-1* Comparators
.
[197] RS Flipflop 5
See
parameter group 13-1* Comparators
.
[198] RS Flipflop 6
See
parameter group 13-1* Comparators
.
[199] RS Flipflop 7
See
parameter group 13-1* Comparators
.
[221] IGBT cooling
Use this option for handling the overcurrent trips. When the drive detects an overcurrent condi-
tion, it shows
alarm 13, Overcurrent
and triggers a reset. If the overcurrent condition occurs for
the 3
rd
time in a row, the drive shows
alarm 13, Overcurrent
and initiates a 3-minute delay before
the next reset.
[231] In power lim. mot.
[232] In power lim. gen.
[233] In power limit
Parameter 5-30 Terminal 27 Digital Output
Table 311: Parameter 5-30 Terminal 27 Digital Output
5-30 Terminal 27 Digital Output
Default value: Size related
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Select the function from the available digital input range and the additional options
[60] Counter A (up)
,
[61] Counter A (down)
,
[63]
Counter B (up)
, and
[64] Counter B (down)
. Counters are used in smart logic control functions. All functions are described in
and
.
Option
Name
Description
[0]
No operation
[1]
Control ready
[2]
Drive ready
[3]
Coast and reset inv
[4]
Enable/no warning
[5]
Running
[6]
Running/no warning
AU373327181955en-000101 / 130R1208 | 161
Danfoss A/S © 2021.08
Parameter Descriptions
VLT® AutomationDrive EZ FC 321
Programming Guide