Art: 714371-00E
Rev
. Date: 06-Aug-12
9-3
PREFERENCE WINDOW:
for
I
nstrument
o
ptIons
Option
Description
Default
Comments
PASSWORD
0-5 digit password to access Set Clock, the Change function in
Customization, and Utility under the Administration Menu.
No password
Password protection for the Set Clock function can be
enabled or disabled. See below.
DATE FORMAT
mm/dd/yy or dd/mm/yy
mm/dd/yy
For Clock Set function only.
INACTIVITY TIMEOUT
Number of seconds after a result is displayed and no operator
intervention that an analyzer will turn off. Allowable range is 45 to 1620
seconds.
120 seconds
SOUND
If enabled, the analyzer will emit a beep after each successful key press,
when results are ready or when a Quality Check message is displayed.
Beep enabled
If Sound is disabled, the analyzer will only beep after a
successful barcode entry.
ENABLE WIRELESS
CUMMUNICATION (U.S.
CUSTOMER USE ONLY)
Enable the wireless functionality in an i-STAT 1 Wireless handheld
Not Enabled
See the "Procedure for Using the i-STAT 1 Wireless
Analyzer" Technical Bulletin for full details.
AUTO TRANSMIT
Handheld transmits results when placed in Downloader or Downloader/
Recharger.
Enabled
MEMORY FULL ACTION Not enabled: over-write the oldest record without warning.
Enabled: Warn user (start-up warning) or Lockout (testing disabled until
upload occurs).
Not enabled
Memory Full refers to when the unsent records as recorded
on the Analyzer Status screen reaches 1000. Uploading
does not erase the data from the handheld’s memory.
BATCH MODE TIMEOUT Not active at this time.
DISPLAY PASSWORD
FOR CLOCK PAGE
The default setting is enabled. However it may be useful to disable
password protection for the clock page in the Spring and Fall when
clocks are set forward and backward one hour.
Enabled
SYNCHRONIZE
CLOCK TO CDS
Will synchronize or update the real time clock in the i-STAT 1 handheld
to the Central Data Station's clock at the time of each download.
Not Enabled
This eliminates the need to reset the handheld's clock at the
beginning and end of Daylight Savings Time.
APPLY OPERATOR LIST
TO VIEWING STORED
PATIENT RECORDS
Requires operator to enter their operator ID number to access stored
patient results on the i-STAT 1 handheld.
Not Enabled
This option can help a facility comply with patient privacy
regulations.
LIMIT NUMBER OF
RECORDS IN TRANSMIT
ALL
Allows the user to apply a date range limit to the Transmit All function in
the i-STAT 1 handheld
Not Enabled
This will prevent operators from sending older patient
records that may have already been deleted from the Central
Data Station.
UPLOAD SCHEDULE
Options are Off, or every X hours, where X can be 1 to 65535 hours. If
enabled, the behavior of the analyzer if the schedule is not met can be
specified. Behavior Options are: Warn User (start-up warning message)
or Lockout (testing disabled until upload occurs).
Off: no warning or
lockout.
If no upload schedule is specified and the Memory Full
warning is ignored and Auto-transmit disabled, data will
eventually be overwritten. However, if a handheld has
not been used and the upload interval is exceeded, this
handheld will be inoperable if the lockout option is used.
Summary of Contents for i-STAT 1
Page 1: ...i STAT 1 System Manual Rev Date 20 Jan 12 Art 714336 00L ...
Page 18: ...1 8 Art 714363 00U Rev Date 02 Aug 12 ...
Page 44: ......
Page 90: ......
Page 106: ...9 12 Art 714371 00E Rev Date 06 Aug 12 ...
Page 162: ......
Page 166: ...Art 730292 00A Rev Date 20 Feb 12 4 ...
Page 176: ...10 10 Art 714372 00L Rev Date 30 Jul 12 ...
Page 182: ...11 6 Art 714373 00F Rev Date 17 Jan 11 ...
Page 184: ...12 2 Art 714374 00J Rev Date 25 Aug 11 ...
Page 185: ...Art 714374 00J Rev Date 25 Aug 11 12 3 ...
Page 186: ...12 4 Art 714374 00J Rev Date 25 Aug 11 ...
Page 187: ...Art 714374 00J Rev Date 25 Aug 11 12 5 ...
Page 192: ......
Page 194: ......
Page 214: ...14 20 Art 714376 00M Rev Date 31 Jan 12 ...
Page 216: ...14 22 Art 714376 00M Rev Date 31 Jan 12 ...
Page 218: ...14 24 Art 714376 00M Rev Date 31 Jan 12 ...
Page 220: ...14 26 Art 714376 00M Rev Date 31 Jan 12 ...
Page 222: ...14 28 Art 714376 00M Rev Date 31 Jan 12 ...
Page 224: ...14 30 Art 714376 00M Rev Date 31 Jan 12 ...
Page 226: ......
Page 236: ......
Page 252: ...17 4 Art 714379 00F Rev Date 18 Jul 12 ...
Page 254: ......
Page 294: ...Art 725768 00E Rev Date 04 Jan 12 20 ...
Page 336: ...22 2 Art 714384 00D Rev Date 07 18 06 ...
Page 342: ...22 8 Art 714384 00D Rev Date 07 18 06 ...
Page 348: ...22 14 Art 714384 00D Rev Date 07 18 06 ...
Page 352: ...22 18 Art 714384 00D Rev Date 07 18 06 ...
Page 364: ...22 30 Art 714384 00D Rev Date 07 18 06 ...
Page 384: ...22 50 Art 714384 00D Rev Date 07 18 06 ...
Page 404: ...22 70 Art 714384 00D Rev Date 07 18 06 ...
Page 488: ...Kaolin ACT 4 Art 715878 00M Rev Date 31 Jan 12 ...
Page 536: ......
Page 556: ...Art 714261 00E Rev Date 10 Jan 11 8 ...
Page 560: ...Art 716240 00D Rev Date 03 Mar 10 4 ...
Page 572: ...Art 715617 00D Rev Date 06 11 08 ...
Page 578: ...Art 714547 00F Rev Date 06 11 08 ...
Page 590: ...Art 720735 00B Rev Date 06 11 08 ...
Page 592: ...Art 721106 00B Rev Date 06 11 08 ...
Page 598: ...Art 722831 00A Rev Date 19 Feb 09 ...
Page 610: ...Art 720654 00B Rev Date 06 11 08 ...
Page 614: ...Art 721317 00D Rev Date 13 Aug 12 4 ...
Page 616: ...Art 725703 00A Rev Date 08 Mar 10 2 ...
Page 618: ...Art 721296 00A Rev Date 07 16 08 ...
Page 620: ...REV DATE 16 Oct 12 ART 714446 00L ...
Page 627: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 6 REV DATE 16 Oct 12 ART 714446 00L ...
Page 628: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 7 REV DATE 16 Oct 12 ART 714446 00L ...
Page 629: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 8 REV DATE 16 Oct 12 ART 714446 00L ...
Page 630: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 9 REV DATE 16 Oct 12 ART 714446 00L ...
Page 658: ......