Item
Description
Watts
Displays the calculated primary quantity based on
the user-selected voltage and current multipliers; VT
configuration (line-to-line or line-to-ground), single-
phase or three-phase, and measured secondary
voltage and current.
VAr
Displays the calculated primary quantity based on
the user-selected voltage and current multipliers, VT
configuration (line-to-line or line-to-ground), single-
phase or three-phase, and measured secondary
voltage and current.
VA
Displays the calculated primary quantity based on
the user-selected voltage and current multipliers, VT
configuration (line-to-line or line-to-ground), single-
phase or three-phase, and measured secondary
voltage and current.
Table 11:
REMOTE VOLTAGE BIAS
Item
Description
Voltage
Displays the Remote Voltage value provided to the
control utilizing either DNP 3.0, MODBUS or IEC
61850 protocols. If a voltage value is present the
control is utilizing the Remote Voltage Bias Voltage
to control.
Table 12:
SECONDARY STATUS
Item
Description
Load Voltage
Displays the real-time measured value of voltage at
the regulator or transformer and includes any
corrections made using the user‑selected VT
correction voltage.
Meter Out Voltage
Displays the measured voltage at the terminals of the
TCC300 without any software modifications. Used
as the base for normalizing voltage.
Source Voltage
Displays the calculated primary source voltage
based on the user selected source voltage multiplier,
source VT corrections and source secondary
voltage.
Compensated Voltage
Displays the calculated voltage at the "load center".
Normalizing Voltage
A Normalizing Voltage Multiplier with a range of 0.80
to 1.20 is available to be applied to Meter Out Voltage
and displayed in real time as Normalizing Voltage.
Load Current
Displays the real-time measured value of current.
Power Factor
Displays the real-time calculated value of power
factor.
Table continues on next page
1VAC388793-MB A
Section 4
TCC600
TCC300
153
User Manual
Summary of Contents for TCC300
Page 1: ...Digital Tapchanger Control TCC300 User Manual ...
Page 2: ......
Page 3: ...Document ID 1VAC388793 MB Issued 2016 08 10 Revision A Copyright 2016 ABB All rights reserved ...
Page 26: ...20 ...
Page 34: ...28 ...
Page 91: ...1VAC388793 MB A Section 3 Operation TCC300 85 User Manual ...
Page 126: ...120 ...
Page 176: ...Section 4 1VAC388793 MB A TCC600 170 TCC300 User Manual ...
Page 260: ...254 ...
Page 328: ...322 ...
Page 494: ...488 ...
Page 556: ...550 ...
Page 580: ...574 ...
Page 600: ...594 ...
Page 700: ...694 ...
Page 710: ...704 ...
Page 712: ...706 ...
Page 713: ...707 ...
Page 714: ......
Page 715: ......