370 Parameters
Calculated number of pole pairs in the motor.
0
0…1000
Number of pole pairs.
1 = 1
Switches the rotation direction of motor. This parameter can
be used if the motor turns in the wrong direction (for example,
because of the wrong phase order in the motor cable), and
correcting the cabling is considered impractical.
Note:
• Changing this parameter does not affect speed reference
polarities, so positive speed reference will rotate the motor
forward. The phase order selection just ensures that
“forward” is in fact the correct direction.
U V W
Normal.
0
U W V
Reversed rotation direction.
1
No.
Name/Value
Description
Def/FbEq16