Parameters 319
Monthly peak
power value
(resettable)
Value of the peak power during the present month, that is,
since midnight of the first day of the present month.
You can reset the value by setting it to zero.
0.00 kW
-3000.00 …
3000.00 kW
Peak power value.
10 = 1 kW
Date of the peak power during the present month.
1/1/1980
1/1/1980...6/5/2159
Date.
N/A
Time of the peak power during the present month.
00:00:00
Time.
N/A
Monthly total
energy (resettable)
Total energy consumption from the beginning of the present
month.
You can reset the value by setting it to zero.
0.00 kWh
-1000000.00 …
1000000.00 kWh
Total energy.
0.01 = 1 kWh
Total energy consumption during the previous month, that is,
between midnight of the first day or the previous month and
midnight of the first day of the present month.
0.00 kWh
-1000000.00 …
1000000.00 kWh
0.01 = 1 kWh
Value of the peak power over the drive lifetime.
0.00 kW
-3000.00 …
3000.00 kW
Peak power value.
10 = 1 kW
Date of the peak power over the drive lifetime.
1/1/1980
Date.
N/A
Time of the peak power over the drive lifetime.
00:00:00
Time.
N/A
46
46 Monitoring/scaling
settings
Speed supervision settings; actual signal filtering; general
scaling settings.
Defines the maximum speed value used to define the
acceleration ramp rate and the initial speed value used to
define the deceleration ramp rate (see parameter group
). The speed acceleration and
deceleration ramp times are therefore related to this value
(
not
).
Also defines the 16-bit scaling of speed-related parameters.
The value of this parameter corresponds to 20000 in e.g.
fieldbus communication.
1500.00 rpm
0.10…30000.00
rpm
Acceleration/deceleration terminal/initial speed.
1 = 1 rpm
No.
Name/Value
Description
Def/FbEq16
Summary of Contents for ACS560
Page 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Page 4: ...4...
Page 30: ...30 Start up control with I O and ID run...
Page 32: ...32 Using the control panel...
Page 100: ...100 Program features...
Page 153: ...Control macros 153...
Page 160: ...160...
Page 374: ...374 Parameters...
Page 408: ...408 Additional parameter data...
Page 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Page 504: ...504 Control chain diagrams...
Page 508: ...508 Parameterization with drive composer...
Page 512: ...512 Parameterization with automation builder drive manager...