234 Parameters
Activates (or selects a source that activates) the speed
controller autotune function. See section
(page
The autotune will automatically set parameters
and
The prerequisites for performing the autotune routine are:
• the motor identification run (ID run) has been successfully
completed
• the speed and torque limits (parameter group
have been set
• speed feedback filtering (parameter group 90 Feedback
selection), speed error filtering (
) and zero speed (
) have
been set, and
• the drive has been started and is running in speed control
mode.
WARNING:
The motor and machinery will run against
the torque and speed limits during the autotune
routine. MAKE SURE IT IS SAFE TO ACTIVATE THE
AUTOTUNE FUNCTION!
The autotune routine can be aborted by stopping the drive.
0?1 = Activate speed controller autotune
Note:
The value does not revert to 0 automatically
Off
0
0
On
1
1
Speed controller
autotune mode
Defines a control preset for the speed controller autotune
function. The setting affects the way the torque reference will
respond to a speed reference step.
Smooth
Slow but robust response.
0
Normal
Medium setting.
1
Tight
Fast response. May produce too high a gain value for some
applications.
2
Mechanical time constant of the drive and the machinery as
determined by the speed controller autotune function. The
value can be adjusted manually.
0.00
0.00...1000.00 s
Mechanical time constant.
100 = 1 s
Defines an added torque value used by the autotune function.
This value is scaled to motor nominal torque.
Note that the torque used by the autotune function can also
be limited by the torque limits (in parameter group
)
and nominal motor torque.
10.00
0.00...100.00%
Autotune torque step.
100 = 1%
Defines a speed value added to the initial speed for the
autotune routine. The initial speed (speed used when
autotune is activated) plus the value of this parameter is the
calculated maximum speed used by the autotune routine. The
maximum speed can also be limited by the speed limits (in
parameter group
) and nominal motor speed.
The value is scaled to motor nominal speed.
Note:
The motor will exceed the calculated maximum speed
slightly at the end of each acceleration stage.
10.00
No.
Name/Value
Description
Def/FbEq16
Summary of Contents for ACS560
Page 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Page 4: ...4...
Page 30: ...30 Start up control with I O and ID run...
Page 32: ...32 Using the control panel...
Page 100: ...100 Program features...
Page 153: ...Control macros 153...
Page 160: ...160...
Page 374: ...374 Parameters...
Page 408: ...408 Additional parameter data...
Page 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Page 504: ...504 Control chain diagrams...
Page 508: ...508 Parameterization with drive composer...
Page 512: ...512 Parameterization with automation builder drive manager...